Description of your pH Perfect

1.1 Identifi cation of parts

The pack contains the items shown and required to install your pH Perfect:

1

  pH Perfect controller

2

  Wall bracket

3

  Wall fi xture kit (2 plugs & 2 screws)

4

  Polyethylene inlet tube (5 meters)

5

  Intake pipe with 2-meter PVC tube and 3-meter cable

6

 FPM lipped injection fl ap valve (3/8”)

7

  pH Sensor model Z35H1P-17 with 5-meter shielded cable

8

  Injection fl ap 1/2” to 3/8” valve reducer

9

  Sensor holder, model PSS3 (1/2”)

10

 - 

11

 Collar for fi xing the injection valve and sensor holder (DN 50 mm)

12

 Buffer solution kit pH 4, pH 7, H

2

O (tap water only)

1

1

2

3

4

5

6

7

8

9

10

11

12

2

1.2 The Control Panel

1

2

3

4

5

6

7

8

9

10

11

12

13

1

  Blue Backlighted LCD  1 line 16 white character screen.

Left side warning zone (alarms) / Right side pH display

2

  Peristaltic pump.

3

  Connection for linking polyethylene inlet tube.

4

  Connection for linking the PVC intake pipe to the suction cane.

5

  Cable gland: for passing the control cable directly to the fi lter (220-240V AC only when fi ltration is in 

progress).

6

  Cable gland: for passing the cable linking the unit to the intake pipe sensor.

7

  Cable gland: for passing the 220-240V AC power cable.

8

  BNC socket for connecting the pH sensor: The sensor cable is connected to the regulator unit with 

this connector.

9

  Master switch: for powering the control unit.

10

  Navigation button “

q

”: for navigating in the “Settings” menu.

11

  “SET/Esc” button: button for exiting from the “Settings” menu; also for displaying the pH set point 

when pressed continuously.

12

  Navigation button “

p

”for navigating in the “Settings” menu.

13

  “CAL/Enter” button: button for enabling the sensor calibration mode (the button must be pressed 

for 5 seconds). This is also used for accepting changes in the “Settings” menu.

3

20

21

EN

Содержание pH Perfect

Страница 1: ...osage 10 4 5 Alkalinity level 10 4 6 OFA over feed protection 10 4 7 Type of calibration 11 4 8 Detection that ltration is in progress 11 4 9 Resetting the appliance 11 Care and maintenance of your pH...

Страница 2: ...Blue Backlighted LCD 1 line 16 white character screen Left side warning zone alarms Right side pH display 2 Peristaltic pump 3 Connection for linking polyethylene inlet tube 4 Connection for linking...

Страница 3: ...n the ltration system THE DISTANCE BETWEEN THE SENSOR AND THE INJECTION POINT MUST NOT BE LESS THAN 60 CM The injection point must be the last element on the return line before the pool Keep the senso...

Страница 4: ...appliance indicates the measurement reliability of the sensor expressed as a percentage 7 After 30 seconds the appliance indicates the measurement reliability of the sensor expressed as a percentage...

Страница 5: ...age displayed on the pH Perfect is French A You can choose between 6 languages for the LCD display French English German Spanish Italian and Dutch To change language when in the Settings menu enable t...

Страница 6: ...Accept the choice by pressing the CAL Enter button E F Special functions of the OFA To prevent false alarms just after installing a pH Perfect if the pH is poorly balanced and the chlorine needed ther...

Страница 7: ...larly during the bathing season Zodiac Pool Care Europe cannot be held liable if these rules are not followed To fit your pool with a global automated water treatment system we recommend that you use...

Страница 8: ...arranty on spare parts shall only be effective after an analysis and expertise by our company of the returned parts followed by the decision to replace them In all cases the legal vendor warranty cont...

Отзывы: