Page 48/68
INSTALLATION AND CIRCUIT – Connection of options
Example 3
You want to add:
A 60W GPS,
A 60W radio,
A 120W audio warning.
A
and
B
Bilge fan
Miscellaneous
lighting
Radio 60W
Miscellaneous
electronic equipment
Depth sounder
Shower pump
GPS 60W
Max power
120W (> 60W)
Searchlight
Alarm system
Refrigerator
VHF
Σ
120W (< 180W)
CONCLUSION
NOTE:
Some manufacturers will indicate the amperage rather than the absorbed
power. For direct current (the case here), simply multiply by 12 to obtain
the power and divide the power by 12 to obtain the device's current
consumption.
IV-2-8-2-Wiring
1
Choose a free fuse location,
d
Connect the power supply of your accessory to the terminal corresponding to this slot
using a 6mm female tab type terminal lug,
e
If you have to add cable for the connection, use cable with a cross-section of at least
1.5mm² complying with "navy" type recommendations (UL1426 or SAE J378 or SAE J1127
or SAE J1128 or in general meeting ABYC and/or EC recommendations),
f
Connect the earth cable of your accessory to the ground terminal strip using a Ø5 "ring
terminal" (same remark as previously for the cable),
g
Insert an ATO type fuse with a max current of 15A and greater than the load current of
your device.
Содержание NZO 700
Страница 1: ...Page 1 68 E N G L I S H Owner s Manual Volume 2...
Страница 32: ...Page 32 68 INSTALLATION AND CIRCUIT Electricity IV 2 Electricity IV 2 1 Layout diagram...
Страница 33: ...Page 33 68 E N G L I S H INSTALLATION AND CIRCUIT Electricity IV 2 2 Drawings of the master wiring harness...
Страница 37: ...Page 37 68 E N G L I S H INSTALLATION AND CIRCUIT Electricity LS option Lights Lights LS option...
Страница 61: ...Page 61 68 E N G L I S H LABELLING V 1 POSITION OF SAFETY LABELS AND REGISTRATION PLATES 8 3 4 5 7 2 6 1 9...
Страница 62: ...Page 62 68 LABELLING V 2 DESCRIPTION OF SAFETY LABELS AND REGISTRATION PLATES 1 4 3 2...
Страница 66: ...Page 66 68 LOCATION OF OPTIONAL ACCESSORIES VI 3 PLOTTER VHF not supplied VHF Plotter...