INSTALLATION AND CIRCUIT
The circuit-breaker isolates the console unit power supply.
NOTE:
After each use, set the circuit breaker back to OFF.
The battery couplers allow the engines to be started either with one battery per engine,
or by coupling the batteries (in parallel), or with a single battery.
IV-2-7-Table of possible configurations
COUPLER STATE
RESULT
COUPLER 1 SET TO "OFF"
COUPLER 2 SET TO "OFF"
THE ENGINES AND THE
BATTERIES ARE ISOLATED
COUPLER 1 TO "BAT 1"
COUPLER 2 TO "BAT 2"
EACH ENGINE STARTS WITH
ITS RESPECTIVE BATTERY.
ALWAYS PUT THE COUPLERS
IN THIS CONFIGURATION
COUPLER 1 TO "BAT 1"
COUPLER 2 TO "BAT 1"
BOTH ENGINES START WITH
BATTERY 2 (used when battery
1 fails)
COUPLER 1 TO "BAT 2"
COUPLER 2 TO "BAT 2"
BOTH ENGINES START WITH
BATTERY 2 (used when battery
1 fails)
COUPLER 1 SET TO "BOTH" COUPLER 2 SET TO "BOTH"
BOTH ENGINES ARE STARTED
BY COUPLING THE 2
BATTERIES
Содержание NZO 700
Страница 1: ...Page 1 68 E N G L I S H Owner s Manual Volume 2...
Страница 32: ...Page 32 68 INSTALLATION AND CIRCUIT Electricity IV 2 Electricity IV 2 1 Layout diagram...
Страница 33: ...Page 33 68 E N G L I S H INSTALLATION AND CIRCUIT Electricity IV 2 2 Drawings of the master wiring harness...
Страница 37: ...Page 37 68 E N G L I S H INSTALLATION AND CIRCUIT Electricity LS option Lights Lights LS option...
Страница 61: ...Page 61 68 E N G L I S H LABELLING V 1 POSITION OF SAFETY LABELS AND REGISTRATION PLATES 8 3 4 5 7 2 6 1 9...
Страница 62: ...Page 62 68 LABELLING V 2 DESCRIPTION OF SAFETY LABELS AND REGISTRATION PLATES 1 4 3 2...
Страница 66: ...Page 66 68 LOCATION OF OPTIONAL ACCESSORIES VI 3 PLOTTER VHF not supplied VHF Plotter...