Page 11
Page 10
MagnaPool™ | Installation Manual
Section 5. Install the pH Link or
Dual Link Module on the Controller
NOTE:
Water care modules are optional accessories and
will not be included with all models.
If your controller model does not have a Dual-Link or
pH Link module you may skip to Section 6.
The controller must be installed and operational
before you Install the module, refer to Section 4.
pH balance and suitable alkalinity levels in the water
must be maintained. Be sure to prepare and balance
the pool before installing the pH Link or Dual Link
module, for details see Section 6.
1.
Turn OFF and disconnect all power to the
controller.
2. Remove the front cover from the controller, see
section 4.3.1 for details.
3. Connect Sens and Pump wires from the Module
to the controller board see section 4.3 for wiring
details.
4. Seat the Module housing on the controller.
5. Fasten two screws to secure the module
to the controller.
6. Replace the external cover.
Figure 11. Dual Link Module Installed
WARNING
Do not reconnect power supply until all components
are installed: (1) pH Link/Dual Link module, (2) POD
kit, and (3) pH down injection pipe.
5.1
Install the POD Kit
1.
Turn off and disconnect all power to the
controller.
2. For optimal performance, the POD must be installed:
• On a 30 cm length of rigid 40 mm or 50 mm PVC pipe.
• As far as possible from any angles.
• Horizontally.
• Vertically within 30°.
•
After the filtering equipment.
• After any heating device but before the electrolytic cell
or other water treatment equipment.
5.2
Drill the Pipe
1. Inspect the POD O-ring to ensure it is in good
condition and properly seated.
2. Press tabs to remove the upper POD housing
from the lower POD housing.
O-ring
Upper Housing
Lower Housing
Figure 12. POD Assembly
3. Remove the 40 mm adapter from the lower
POD housing.
4. Place the 50 mm guide on the top of the pipe.
NOTE:
For 40 mm installations use the 40 mm adapter
marked “AUS” as the guide for marking the pipe,
for 50 mm installations use just the bottom of
the POD assembly.
5. Mark the pipe through the holes.
6. Drill holes in the PVC pipe using the hole saw.
Make sure the edges are smooth without burrs.
Hole Saw
40 mm Adapter
Figure 13. Mark and Drill Pipe
5.3
Install the POD
1. For 40 mm pipe installations, insert the
adapter into the holes in lower POD housing.
* with 40 mm pipe
Figure 14. Assemble the POD
2. Note the arrows on the upper housing
indicating flow direction. Make sure the pod is
in proper orientation.