Page 5
Page 4
MagnaPool™ | Installation Manual
Section 2. System Overview
2.1
Contents
Before starting, check that you have the correct
parts as indicated in Table 1. If any parts are
missing or incorrect, please call your local distributor
or technical support at 1300 763 021 for assistance.
2.1.2
Water Care Module Contents
pH Link, Dual Link
a. Module (pH Link or Dual Link)
b. POD Housing Upper
c. POD Housing Lower
d. 40 mm Pipe Adapter
e. POD Cap
f. Cap Plug (X2)
g. pH Injector Valve
h. Hole Saw and Hex Key
i. Compression Fitting
j. Ceramic Weight
k. 6 mm Tube (5 m)
l. Acid Cap, 5 L
m. Acid Cap, 15/20 L
n. Locking Collar
o. Locking Collar Tool
p. pH Sensor
q. ORP Sensor*
r. Sensor Holder (X2*)
*Items only included with eXO
®
- Pro iQ
pH Buffer Solutions: pH 7 (X6), pH 4 (X6) - (not shown)
ORP 470 mV Buffer Solution (X6) - (not shown)
Table 2. Water Care Module System Contents
2.1.1
Hydroxination System
Clearwater, eXO
®
, Hydroxinator
(all models)
a. Controller
b. Temperature Sensor*
c. Wall Mount Bracket
d. Wall Mount Screws Ø7 mm (X2)
e. Wall Mount Anchor (X2)
f. Electrolytic Cell
g. Unions (X2)
h. Glue on Adapter (X2)
i. Adapter O-Rings (X2)
j. Pipe Reducer - White (X2)
k. Zip Ties (X7) - (not shown)
*Items not included with all models.
Table 1. Hydroxination System Contents
2.2
Specifications
2.2.1
Hydroxination System
Compact
Mid
Large
Nominal chlorine production
18 g/h
25 g/h
35 g/h
Nominal output amps
3.6 A
5.0 A
7.2 A
Required mineral level
4000ppm
Power supply voltage
240 VAC - 50 Hz
Electric power
200 W
Protection index
IP43
Flow through the cell
Min. 80 Lpm
Max pressure in the cell
2.75 bar
Operating water temperature
10°C - 40°C
Table 3. Hydroxination System Specifications
2.2.2
Water Care Module
Power Supply
Extra low voltage
(connected to controller)
Peristaltic pump flow rate
1.2 L/h
Maximum back pressure (injection)
1.5 bar
pH correct
Acidic pH only
(sulfuric/hydrochloric acid)
pH sensor calibration
1 or 2 point (pH 4 and pH 7)
Sensor Cable Length
3 Meters
ORP sensor calibration*
1 point (470 mV)
*Applicable only to eXO
®
- Pro iQ
Table 4. Water Care Module Specifications
NOTE:
Water care
modules are optional
accessories and will
not be included with
all models.
Содержание MagnaPool