3.5 Manual Start and Stop
Up to eight (8) speeds may be started from the
controller. Manual operation of speeds "eStar" through
"4" differs from manual operation of speeds "5" through
"8".
NOTE
When starting the pump, the pump will first run
at the priming speed for the priming duration, as
set by the installer.
Speeds eStar through 4
To start the pump manually running at speeds
"eStar" through "4", press button "
" through "4"
corresponding to the desired speed. The associated LED
will light red and the controller enters the
RUN
mode.
2
3 4
MENU
2:SPEED 2
10:00AM RPM: 1200
To stop the pump, press the button again. The associated
LED will extinguish and the pump and controller will
return to the
OFF
mode.
Speeds 5 through 8
To start the pump manually at speeds "5" through
"8", press the
MENU
button. The controller displays
SELECT PRESET/N:LABEL
, where n:label is the
number and label of the last selected speed "5" through
"8".
Using the arrow keys, select the desired speed to
activate, and then press
MENU
to enter
RUN
mode,
starting the pump running at the selected speed.
2
3 4
SELECT PRESET
5:SPEED 5
MENU
To stop the pump, press
MENU
. To exit without starting
the pump, press any button "
" through "4".
3.6 Pump Speed Setting
With the exception of preset "
", each speed may be
adjusted while the pump is running in that speed mode.
Preset "
" is reserved for the eStar function, and its
speed is set by the installer.
To adjust the pump speed, the controller must be in the
RUN
mode. While in
RUN
mode, the controller displays
the pump speed. Adjust the speed by pressing the up or
down arrow keys. The speed is saved by the controller
and will remain until changed again.
NOTE
Pump speed is adjustable only within a certain
range. The minimum and maximum limits of the
range are set by the installer.
NOTE
When used with a solar heat system, set speed
to at least 3000 RPM and potentially up to 3450
RPM, based on the pump's head required to
push the water up a minimum of 12-15 feet.
2:SPEED 2
10:00AM RPM: 1400
3.7 Timeclock Setup and Operation
NOTE
The controller has a non-replaceable battery back-up
that keeps time, programs, and speed settings when power is
disconnected and should never require replacement.
The controller allows the user to create timed pump
programs on pump speeds (presets) "
" and "2". The
two timers operate independently of each other, and may
overlap in time if desired.
Timeclock Setup
Start the desired speed, "
" or "2". Press
MENU
. The
controller enters the Timeclock setup mode. Using the
arrow keys, select
ON TIME
and press
MENU
. Set the
desired pump turn-on time using the arrow keys and
press
MENU
. The time is stored. Select
OFF TIME
using
the arrow keys and press
MENU
. Set the desired pump
turn-off time using the arrow keys and press
MENU
. The
time is stored.
2:SPEED 2 TIMECLOCK
ON TIME
Using the arrow keys, select
TIMECLOCK
. Select
ENABLE
using the arrow keys. The program is now
enabled to run. Press the speed button ("
" or "2") to
return to the
RUN
mode.
PAGE 12
JEP-R Variable-Speed Pump Controller
|
Installation Manual
ENGLISH