background image

The table below shows how to set the address of the 

iAquaLink board. Short means that a jumper is installed. 

Open means that a jumper is not installed.

ID01

ID0

Address

Short

Short

1

Short

Open

2

Open

Short

3

Open

Open

4

4.6 

LED Status Indicator Lights

Normal Operating Mode

Function

LED Indication

Power (Red)

ON = Power

OFF = No power

Network Connection

(Orange)

ON = Connected

Flashing/OFF = WiFi/Network

not connected/searching

Online Status

(Green)

ON = On-Line

OFF = Off-Line

4.7 

Product Registration

NOTE 

Make sure all three (3) LED status indicator 

lights are illuminated before proceding to 

product registration.

To register your iAquaLink Web Connect Device, please 

go to 

www.iAquaLink.com/ssid

 and follow the online 

registration instructions.

4.8 

iAquaLink Apps and Web Interface

IMPORTANT

Prior to accessing the Smart Device App and Web 

Browser Interface, make sure the installation and 

registration of the iAquaLink Web Connect Device 

has been completed succesfully.

4.8.1  Mobile Smart Device Apps

The smart device apps offer basic automation solution 

to control the pool and spa features anytime, anywhere.
Free iAquaLink smart device apps are available for 

devices such as Android

®

, iPhone

®

, iPad

®

, iPod Touch

®

or any other HTML5 enabled device.

To download your App:

 

Go to iTunes App Store

SM

 and search Zodiac iAquaLink, 

for iPhone

®

, iPad

®

, or iPod Touch

®

.

 

Go to the Android Market and search Zodiac iAquaLink, 

for any Android

®

 device.

For instructions on how to use the smart device app, 

see the Welcome Brochure (P/N H0369500) included in 

your iAquaLink package.

4.8.2  Web Browser Interface

Using your home personal computer or laptop, you can 

use the iAquaLink web interface to program, customize, 

control, and configure every device and feature 

available with your AquaLink RS and PDA systems.

How to Access the Web Browser Interface:

 

Go to www.iAquaLink.com and log in to your account.

 

On the iAquaLink Owner's Center page, click 

"Locations". If you have not done this step yet, follow the 

online instructions to add your device.

 

Once your device is added to the list, click on it then 

a separate window browser will display a "Waiting for 

connection..." message followed by the HOME screen of 

your iAquaLink Web Interface.

Page 11

iAquaLink™ Web Connect Device for AquaLink

®

 RS and PDA Control Systems   

|

   Installation Manual

ENGLISH

  

 

Содержание iAquaLink

Страница 1: ...ay not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to com...

Страница 2: ......

Страница 3: ...or Lights 11 4 7 Product Registration 11 4 8 iAquaLink Apps and Web Interface 11 4 8 1 Mobile Smart Device Apps 11 4 8 2 Web Browser Interface 11 Section 5 Web Interface Home Screen 12 5 9 1 Title Bar...

Страница 4: ...are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant...

Страница 5: ...s or enclosures containing other conductors unless the additional conductors are also protected by a ground fault circuit interrupter Refer to local codes for complete details SAVE THESE INSTRUCTIONS...

Страница 6: ...be updated to revision R or later The iAquaLink Web Connect Device can be used in addition to an existing PDA control system however the firmware in the power center must be updated to revision 6 0 o...

Страница 7: ...Unscrew and remove the power center PCB and bezel assembly from the power center See Figure 2 4 Remove the CPU board from the power center PCB 5 For an RS system install the new CPU board revision R...

Страница 8: ...iAquaLink J Box and the power center The transceivers do not require line of sight to communicate 4 1 Outdoor Installation WARNING Potentially high voltages in the power center can create dangerous e...

Страница 9: ...ove the dead panel 5 Pull cable through the knockout with the Heyco or equivalent fitting and into the low voltage compartment See Figure 4 6 Strip back the insulation jacket of the cable approximatel...

Страница 10: ...ection 4 4 To Set Up the J Box for Wired Connection 1 Remove the two 2 screws that secure the cover and gasket on the iAquaLink J box Remove the gasket and cover See Figure 5 2 Connect one end of the...

Страница 11: ...o control the pool and spa features anytime anywhere Free iAquaLink smart device apps are available for devices such as Android iPhone iPad iPod Touch or any other HTML5 enabled device To download you...

Страница 12: ...figure below the iAquaLink menu screen displays the following layout The title bar The middle info panel The navigation bar iAquaLink Home Menu OneTouch Help Back Status FILTER PUMP SPA POOL HEAT Pool...

Страница 13: ...en 6 1 Menu Screen The MENU screen provides access to the main links to program set up schedule and customize your pool spa system 6 1 1 To Display the Menu Screen HOME MENU On the HOME screen click t...

Страница 14: ...nly one piece of equipment can be selected at a time Second Step Programming the new device On the SCHEDULE screen the added equipment will be displayed and highlighted in the circuit list Also the ED...

Страница 15: ...ge General Items Filter Pump VSP Pump Spa Pool Heat Spa Heat Label One Label Two Label Three Label Four Label Five Label Six Label Seven Thu June 23 2011 3 03 PM Home Menu OneTouch Help Back Status Cu...

Страница 16: ...connection screen is displayed but override switches at the power center do not operate at all 1 Damaged or improperly installed CPU board 2 Wrong CPU board 3 Damaged power center PCB 1 Check alignme...

Отзывы: