refrigerant has been drained.

• 

The label must be dated and signed.

• 

For appliances containing a flammable refrigerant, check that labels are placed on 

the equipment stating that it contains a flammable refrigerant.

RECOVERY

• 

When draining the refrigerant for maintenance or decommissioning, best practices 

should be followed in order to safely drain all of the refrigerant.

• 

When  transferring  refrigerant  to  a  cylinder,  make  sure  that  you  use  a  recovery 

cylinder that is compatible with the refrigerant. Make sure that the correct number 

of cylinders are provided for recovering all of the refrigerant. All cylinders used must 

be intended for the recovery of refrigerant and must be labelled for this specific 

refrigerant. The cylinders must be equipped with a vacuum valve and a stop gate 

in good working order. Empty collection cylinders are drained and, where possible, 

cooled before recovery.

• 

The recovery equipment must be in good working order, the instructions for using 

the equipment must be within reach and the equipment must be compatible for 

use  with  the  refrigerant  concerned,  including,  where  appropriate,  a  flammable 

refrigerant.  Moreover,  a  set  of  calibrated  scales  must  be  available  and  in  good 

working order. The pipework must be complete, have no leaks or disconnected 

connectors, and must be in good condition. Before using the recovery unit, check 

that  it  is  in  good  working  order,  that  it  has  been  well  maintained  and  that  the 

associated electric components are sealed so as to prevent any risk of fire in the event 

of refrigerant being released. If you have any doubts, contact the manufacturer.

• 

The recovered refrigerant must be sent to the refrigerant supplier in its recovery 

cylinder with a waste transfer note. Do not mix different refrigerants in the recovery 

units, and in particular in the cylinders.

• 

If the compressor has been removed or if oil from the compressor has been drained, 

check that the refrigerant has been completely removed to prevent it from mixing 

with the lubricant. The draining process must be carried out before returning the 

compressor to the supplier. Only the electric heater of the compressor body can 

be used to accelerate this process. This operation can be carried out safely once all 

liquids within the system have been drained.

Содержание HPO

Страница 1: ...H0721600_REVA 2021 05 HPO EN Instructions for installation and use English Heat pump Translation of the original instructions in French More documents on www zodiac com...

Страница 2: ...the risk of injury occurring when working on the appliance Before handling the appliance check that it is switched off and isolated The appliance is intended to be used for pools and spas for a speci...

Страница 3: ...pply and that all other equipment or accessories connected to the appliance are also disconnected from the power circuit Do not disconnect and reconnect the appliance to the power supply when in opera...

Страница 4: ...ing maintenance work ensure there are no traces of corrosion or oil around the cooling components Before beginning work on the cooling circuit stop the appliance and wait for a few minutes before fitt...

Страница 5: ...t be compatible for use with the refrigerant concerned including where appropriate a flammable refrigerant Moreover a set of calibrated scales must be available and in good working order The pipework...

Страница 6: ...Technical specifications 25 5 3 I Dimensions and marking 26 Tip to make it easier to contact the retailer Write down the retailer s contact details to help you find them more easily and fill in the pr...

Страница 7: ...or installing the anti vibration pads The appliance must not be installed With the blowing towards any permanent or temporary obstacle less than 4 metres away Within range of watering nozzles sprays o...

Страница 8: ...ss must be installed to make it easier to work on the appliance Water inlet valve By pass valve Water outlet valve Water inlet adjustment valve optional Water outlet adjustment valve optional Water tr...

Страница 9: ...installed The appliance is provided for connection to a general power supply with a TT or TN S neutral regime Electrical protection by circuit breaker D curve rating to be defined according to the ta...

Страница 10: ...said to be slaved to the heating system Filtration is kept in operation or activated if the pool temperature falls below the desired temperature For the connection connect the filtration timer to ter...

Страница 11: ...tinuous operation 24 7 To maintain the temperature throughout the season run automatic circulation for the equivalent of the water temperature divided by two the longer this time the more sufficient t...

Страница 12: ...er inlet valve By pass valve Water outlet valve Water inlet adjustment valve optional Water outlet adjustment valve optional An incorrect by pass setting may cause the heat pump to malfunction Check t...

Страница 13: ...ING COOLING operating mode is selected the heat pump automatically switches to HEATING mode if the water temperature falls 1 C below the temperature setpoint or to COOLING mode if the water temperatur...

Страница 14: ...ng requirements and silent operation desired Cooling hot zones heat waves sheltered pools etc The compressor speed directly affects the appliance s power output Press BOOST SMART or SILENCE the indica...

Страница 15: ...that the appliance undergo general servicing at least on a yearly basis to ensure its proper operation maintain performance levels and prevent any possible failures These operations are carried out a...

Страница 16: ...g maintenance work a leak detector must continuously monitor for leaks at the most critical point in order to report any potentially hazardous situation Particular attention must be paid to the follow...

Страница 17: ...is complete if this is not already the case Pay close attention to not overfilling the cooling system Before recharging the system carry out a pressure test using a suitable purge gas The system must...

Страница 18: ...e the heat pump s operating range It may be that the heat pump has detected an operating fault see 4 2 I Error code display If you have checked these points and the problem persists contact your retai...

Страница 19: ...Possible causes Solutions PP01 Faulty inlet water temperature sensor Sensor disconnected or out of order Reconnect or replace the sensor PP02 Faulty outlet water temperature sensor Sensor disconnecte...

Страница 20: ...water flow rate Check the by pass valve Clogged filter or electronic valve Check refrigerant levels d6 TH3 sensor fault Check the d6 TH3 sensor EE06 Controller fault The connection is faulty Check the...

Страница 21: ...r the propellers are broken Check the fan speed Check the propellers EE16 PFC module protection The data is incorrect Check the printed circuit board The fan motor is faulty Check the fan speed The pr...

Страница 22: ...oo low Check and replace the printed circuit board EE25 Compressor power error The compressor operates with 1 or 2 phases Check the wiring EE26 4 way valve inversion error Blockage inversion of the 4...

Страница 23: ...22 4 3 I Wiring diagramsWiring diagrams 4 3 1 HPO 6 HPO 8 HPO 9 HPO 11 HPO 14 EN...

Страница 24: ...23 4 3 2 HPO 18...

Страница 25: ...iption A HPO B 50 PVC connectors x2 C Anti vibration pads x4 D Winterising cover Heating priority E Remote control kit F Condensate drainage connector x2 G Hose x2 H PAC NET cleaning product Included...

Страница 26: ...3 x 2 5 3 x 4 3G1 5 3G2 5 3G4 Max suction discharge pressure bar 45 Max low pressure high pressure side bar 25 Recommended water flow m h 4 5 6 7 8 10 Sound pressure at 10m max min db A 34 22 36 23 3...

Страница 27: ...d marking Grid User interface Pool water inlet Pool water outlet Front Rear Top Bottom Model HPO 6 HPO 8 HPO 9 HPO 11 HPO 14 HPO 18 A 859 985 1074 B 641 736 941 C 357 357 395 D 97 97 107 E 446 5 537 7...

Страница 28: ...diac Pool Systems LLC All rights reserved ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks are the property of their respective owners ZPCE ZA L...

Отзывы: