6
1.3.4 Connection through a dividing wall
Plan 610 x 410 mm spaces in the wall between the technical room and the pool hall.
In the wall on the pool side, seal the standard grate frame on the bottom (without any equipotential
connection to the sound trap) and the double deflector grate on the top (without any equipotential
connection with the blower elbow).
On the technical room side connect the made to measure metalwork (sound trap, blower elbow) to the
system and fit a foam joint for water tightness and to block any vibrations.
* minimum distance
rear view of the CAE (through the wall)
CAE 508-510-513
suction
blowing
sound trap
blower elbow
double deflector grate
Dimensions in mm, indications of values for installation using accessories for a CAE with mini-duct
network (see Zodiac Pool Care Europe catalogue).
1.3.5 Connection to a duct network
Install the appliance in a technical room that is protected from freezing.
Connect the intake and blower duct (or standard parts) respecting the air circulation direction:
- intake: behind the system (standard 825 x 405 mm frame)
to the right of the system (standard 559 x 465 mm frame)
to the left of the system (standard 559 x 465 mm frame)
-
hot dry air blower
: from the top, from the front or from the rear of the upper box on the system
(standard 405 x 350 mm frame).
Minimum cross section for blower and intake ducts
Appliance
Unit
CAE 508
CAE 510
CAE 513
Rectangular duct
mm
400 x 400
500 x 500
500 x 500
Circular duct
mm
400
500
500
Cross section for a maximum length of 20 meters, air speed: 5 to 6 meters/second
Average load losses by air flow direction change, 90° elbow or by T = 1 mm EC
To ensure the correct operation of the system, the duct network must be sized
according to the air flow delivered by the appliance (see table below).
For very long or complicated networks please contact us.
The blower grates must be fitted with registers for better air distribution.
Plan a water drainage point at the low point for possible projection of water in the
ducts.
Swimming
pool hall
Pool
Technical
room
EN
Содержание CAE
Страница 1: ...Air dehumidifier for indoor swimming pools R f N D 006 A 1 Ver 02 2010 CAE Installation instructions...
Страница 22: ...1 Sch ma lectrique Sch ma de puissance CAE 508 510 513...
Страница 23: ...2 Sch ma de commande CAE 508 510 513...
Страница 25: ...4 Dimensions weight without option Kg CAE 508 228 CAE 510 235 CAE 513 240...
Страница 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Страница 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...