Do not fit solar modules and wiring with wet plugs and sockets!
●
Exercise utmost caution when carrying out work on wiring and safety equipment (use insulated
tools, insulated gloves, etc.)!
●
Do not use damaged modules! Do not dismantle modules! Do not mark on the rear of the
module using sharp objects!
●
Exercise utmost caution when working on wiring and the inverter. Be sure carefully to follow
manufacture’s installation instructions!
●
Artificially concentrated sunlight shall not be directed on the modules or panels!
12
、
Danger of death from arcing
!
Modules generate direct current when light shines on them. An arc may be produced when
connections are separated. We therefore recommend covering modules with a lightproof cloth during
installation. When breaking a connected string of modules (e.g. when disconnecting the DC line from
the inverter under load), a lethally strong arc can occur:
●
Never disconnect the solar generator from the inverter while the inverter is connected to the
mains grid—remove the fuse from the AC side on the inverter first!
●
Ensure cable connections in perfect condition (no splitting, soiling or other contamination)!
Remark: all sizes are measured in mm; and tol/- 2 mm