Pelletherm V.4 LT
9
4. TECHNICAL DATA OF THE SYSTEM – A HOT WATER PELLET BOILER FROM
SERIES “PELLETHERM V.4 LT” AND AN AUTOMATED PELLET BURNER FROM
SERIES "GP XX SC”.
Technical parameters of the system, consisting of a hot water pellet boiler from series
“Pelletherm V.4 LT” and an automated pellet burner from series “GP xx sc”, are presented in
Table 4.1.
Table 4.1. Technical parameters of a system – a hot water pellet boiler and an automated
pellet burner.
PARAMETER
DIMENSION
VALUE
Hot water pellet boiler model
-
Pelletherm
18 V.4 LT
Pelletherm
25 V.4 LT
Pelletherm
30 V.4 LT
Pellet burner model
-
GP 20_18
sc
GP 25 sc
GP 32 sc
Nominal heating output of the
system
kW
18
25
30
Heating output adjustment range
kW
7 - 18
7 – 25
10 - 30
Used fuel type
Wood pellets
Pellets category according to
standard EN ISO 17225-2:2014
A1, A2, B
Pellets category (according to the
burner’s manufacture company
categorization)
A, AB, B, BC, C
Mass flow of flue gases*
g/s
10.8
Energy efficiency class according
to regulation
(
Е
U) 2015/1187
-
Efficiency at nominal heating
output mode
℅
92
92
92
CO emissions in the flue gases
(0°C, 1013 mbar) at 10%
О
2
mg/m
3
163.0
Dust emissions in the flue gases
(0°C, 1013 mbar) at 10%
О
2
mg/m
3
14.1
OGC emissions in the flue gases
(0°C, 1013 mbar) at 10%
О
2
mg/m
3
12.8
Boiler class according to standard
EN 303-5:2012
-
5
Flue gas temperature at nominal
heating output mode
ºC
135-155
157-177
153-173
Residues after complete fuel
burning
Ash
The quantity depends on the pellets ash
contain
* The data specified are calculating.
The pellet boiler from series “Pelletherm V.4 LT” is manufactured in two
variants for mounting of the pellet burner – the so called “left mounting” (i.e. the
burner is mounted on the boiler’s left side, when looking in front) and “right
mounting” (i.e. the burner is mounted on the boiler’s right side, when looking in
front of the boiler).
The automated pellet burner from series “GP xx sc” is designated for utilization of
wood pellets with classes A1, A2 and B, according to standard EN ISO 17225-
2:2014, or categories A, AB, B, BC and C according to the manufacture
company’s classification
Содержание GP ** sc