background image

 

TS1200: 

  Tripod Turnstile 

TS1211:

  Tripod Turnstile with Controller and RFID Reader 

TS1222: 

  Tripod Turnstile with Controller and Fingerprint Reader with RFID function. 

Please read this document carefully before installation and using the device. 

1. Technical Specifications 

Input Voltage 

AC 100~120V /200~240V,   

50Hz /60Hz 

Max. Tolerance of Arms 

Center: 80 kg 

End: 40 kg 

Rated Power 

60 W 

Ingress Protection Degree 

IP54 

Operating Environment  Indoor and Outdoor (shelter) 

Arm Length (mm) 

520 

Operating Temperature 

-28ºC ~ 60ºC 

Net Weight 

55kg 

Operating Humidity 

5% ~ 85% 

Gross Weight 

63kg 

Flow Rate 

25~30 passages / minute 

Dimension(mm) Figure 1  L = 600, W = 330, H = 990 

Input Control Signal 

Dry contact 

Package Size (mm) 

L = 730, W = 450, H = 1080 

 

Figure 1

 

 

2. Arm Installation and Equipment Testing 

 

2.1 Arm installation method 

Installation procedure 

1. Using the glue and applying in the hole of the arms as 

well as the one screw, as shown in Figure 2-1. (This is to 
prevent screws from getting loose due to vibration 
after being used for a long time.) 

 

 

 
 
 

 

 

 

 

Figure 2-1 

 

This hole shall be 

applied with glue 

evenly. 

Содержание TS1200 Series

Страница 1: ...TS1200 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Страница 2: ...Indoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 55kg Operating Humidity 5 85 Gross Weight 63kg Flow Rate 25 30 passages minute Dimension mm Figure 1 L 600 W 330...

Страница 3: ...nstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 4 4 Check whether the tripod turnstile and the LED indicators work properly If there is any problem please contact...

Страница 4: ...is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to t...

Страница 5: ...he gaskets provided Note that all the six expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 3 Put the turnstile on the mounting plate and tighten the screws Apply screw secu...

Страница 6: ...ED screen and display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate w...

Страница 7: ...Signal Input otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar...

Страница 8: ...ard each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enabled or disabled t...

Страница 9: ...enter of the arm is 80kg and at the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole e...

Страница 10: ...or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating and check the work status of the solen...

Страница 11: ...any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people con...

Страница 12: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Страница 13: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...

Отзывы: