background image

4. Cable Diagram 

4.1 Function description of the turnstile control board 

If you are using TS1211 or TS1222, all the connections between access control and turnstile control boards are done in 
factory. Just plug in communication cable to access controller and do the setting. 

If you are using TS1200, you need to connect access control system to the control board, please check the content in this 
chapter carefully. 

Warning: 

The third party access control system lock relay trigger time should be 1 second or less than 1 second. 

 

 

  Figure 4-1

 

Descriptions: 

J2 Counter: 

To connect a LED screen and display the number of people passed that is generated by the push of tripod arms, 

each completed push means pass one time.

 

J5 (Right) & J4 (Left) Indicator:

 To connect a LED screen and indicate whether this passage is allowed to pass.

 

J3 Indicator (top): 

To connect a LED screen and indicate if user verification is successful and whether it is able to pass. 

J-NC2 Disabled Turnstile: 

Short circuit NC1 and GND, the turnstile is disabled, that is to say, the turnstile is locked by force.

 

J7 Opening Signal Input:

 To receive relay signal and open the turnstile.

S

hort circuit K1 and GND, left passing is allowed; 

short circuit K2 and GND, right passing is allowed. 

J6 External Alarm:

 Short circuit ALARM1 and GND, and the turnstile is disabled (locked) and the alarm is ringing in case 

Содержание TS1200 Series

Страница 1: ...TS1200 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Страница 2: ...Indoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 55kg Operating Humidity 5 85 Gross Weight 63kg Flow Rate 25 30 passages minute Dimension mm Figure 1 L 600 W 330...

Страница 3: ...nstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 4 4 Check whether the tripod turnstile and the LED indicators work properly If there is any problem please contact...

Страница 4: ...is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to t...

Страница 5: ...he gaskets provided Note that all the six expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 3 Put the turnstile on the mounting plate and tighten the screws Apply screw secu...

Страница 6: ...ED screen and display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate w...

Страница 7: ...Signal Input otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar...

Страница 8: ...ard each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enabled or disabled t...

Страница 9: ...enter of the arm is 80kg and at the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole e...

Страница 10: ...or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating and check the work status of the solen...

Страница 11: ...any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people con...

Страница 12: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Страница 13: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...

Отзывы:

Похожие инструкции для TS1200 Series