TS1000 Pro Series Tripod Turnstile
User Manual
P a g e
|
12
Copyright©2020 ZKTECO CO., LTD. All rights reserved.
Bit Setting
Duration
Bit Setting Duration
111
5s
011
30s
110
10s
010
40s
101
15s
001
50s
100
20s
000
60s
Note:
The turnstile’s opening duration is set to 5s by default.
4.1.2
Direction Indicator
It is to indicate whether people can pass through the gate. The green arrow means passing is allowed
while the red cross "
X
" means that passing is prohibited. The indicator status can be set with number 4 and
5 in the DIP switch. The descriptions of the bit settings are as follows:
11
= One-way traffic; left passing is allowed.
10
= One-way traffic; right passing is allowed.
01
= Passing is allowed in both directions.
4.1.3
Continue Passing Function
With the “Continue Passing” function, the turnstile could remember at most 20 swipes of one card at one
time and allows up to 20 people to pass so they don’t have to swipe card each time. This function can be
enabled or disabled with number 6 in the DIP switch. The descriptions of the bit settings are as follows:
In the DIP switch, number 6 is used to enabled or disabled the
Continue Passing Function
; number 7 is
used to set the initial value of
Continue Passing Function
.
Number
6
Number
7
Function
Opening Duration
0
Disabled
Disabled
Continue Passing
Function
Please refer to section
4.1.1 Setting the Turnstile
Opening Duration.
1
1
Enabled
Continue Passing
Function
The initial value is 16s, and the
Opening Duration
= 16 + (N -1) * 6.
0
The initial value is 8s, and the
Opening Duration
= 8+ (N -1) * 6.
5
Equipment Precautions and Maintenance
Precautions
1. It is recommended to purchase additional accessories to use the product outdoors.
1) You may install cooling fans for the equipment if the working temperature is often above 50 ºC.
2) The device is rated IP54 waterproof under proper installation. However, its ability to stand in
extreme weather conditions, such as typhoon, is not guaranteed.