Appendix 1 Buzzer, Indicator Light Prompt Instructions

When the reader communicates via RS-485, the status of the buzzer and the indicator is shown in the
table below. Note that when communicating via Wiegand, the status of the buzzer and indicator is
controlled by the controller or the all-in-one access control device.

Table 4-1

Buzzer, Indicator Light Prompt Instructions

Working Status

Indicator Light

Buzzer

When the reader is powered on.

LED bright white light,

then switch to white light

breathing state after 4s.

1 short sound

When punching the card.

LED bright white light.

1 short sound

Card is registered

LED indicator lights green.

1 short sound

Card not registered

LED indicator (red) lights up

briefly twice.

2 short sound

If the communication is not normal,

there will be a state that the host does

not poll.

5 seconds after the timeout, the white

light flashes 3 times

3 short sound

Содержание ProlD Series

Страница 1: ...ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please visit our Company s website www zkteco com USER MANUAL Pro...

Страница 2: ...n the manual In case of any conflict between terms and conditions of this manual and the contract specifications drawings instruction sheets or any other contract related documents the contract condit...

Страница 3: ...se of operation of the machine unit equipment beyond the rate limits iii in case of operation of the machine and equipment in conditions different from the prescribed conditions of the manual The prod...

Страница 4: ...of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhan...

Страница 5: ...Device Convention Description Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window...

Страница 6: ...NAL AND WIRING DESCRIPTION 9 2 1 TERMINAL DESCRIPTION 9 2 2 WIRING DESCRIPTION 10 2 2 1 POWER WIRING 10 2 2 2 CONTROLLER CONNECTION 10 2 2 3 ACCESS CONTROL DEVICE CONNECTION 12 2 2 4 TAMPER SWITCH CON...

Страница 7: ...ective use of access control There are two colors of black and white for customers to choose using three installation specifications Asian gang box single gang box and mullion mount standard ID option...

Страница 8: ...r Resistant RFID Access Control Reader User Manual P a g e 7 Copyright 2023 ZKTECO CO LTD All rights reserved ProlD102 ProlD103 Back Plate Figure 1 1 ProlD series water resist and RFID access control...

Страница 9: ...to 13V DC Current Draw 350mA 5V Processor 32 bit ARM Cortex M0 48MHz Card Type ID IC Card Read Range 0 to 5 cm Output Format Wiegand 26bit or 34bit Adjustable RS485 Operating Temperature 20 C to 65 C...

Страница 10: ...3V DC Input Note Recommended AC adapter 7 to 13V Current Draw 350mA 5V GND RS 485 RS485A RS 485 Communication Interface RS485B Wiegand Out WD0 Wiegand Output0 WD1 Wiegand Output1 Wiegand 26 34 WG26 34...

Страница 11: ...3V Current Draw 350mA 5V Use an AC adapter with a higher current rating to share power with the other devices 2 2 2 Controller Connection This ProlD series reader needs to be connected to a host machi...

Страница 12: ...P switch needs to be set with the controller powered off and takes effect after restart After setting the DIP switch does not need to be set back to its original position 5 For details on how to add c...

Страница 13: ...nd Notes When terminal WG26 34 is connected to ground the number of Wiegand output bits is 26 bits The default is not grounded and the number of Wiegand output bits is 34 bits 2 2 3 Access Control Dev...

Страница 14: ...tes The reader RS 485 address defaults to 1 2 2 4 Tamper Switch Connection When the tamper switch terminal is successfully connected to the controller the device will not only send an alarm when the b...

Страница 15: ...ons 3 1 Install on the wall Step 1 Attach the mounting template sticker to the wall and drill holes according to the mounting paper The recommended installation height from the ground is 1 5 meters wh...

Страница 16: ...sian gang box or single gang box mullion mount using two wall mounting screws Step 3 Pass the cables through the wire hole Step 4 Then insert the device into back plate Step 5 Use security screw to fa...

Страница 17: ...or the all in one access control device Table 4 1 Buzzer Indicator Light Prompt Instructions Working Status Indicator Light Buzzer When the reader is powered on LED bright white light then switch to w...

Страница 18: ...evice type you have selected to verify the unique similarity between you and the User ID you have registered You can optionally enter your Name and Code The above information is necessary for you to u...

Страница 19: ...or sake of data security 6 All the personal information in our products can be queried modified or deleted If you no longer use our products please clear your personal data III How we handle personal...

Страница 20: ...nd their quantities Component Name Hazardous Toxic Substance Element Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr6 Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE Chip Resisto...

Страница 21: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2023 ZKTECO CO LTD All Rights Reserved...

Отзывы: