LPRS2000 Hybrid Recognition Integrated Machine User Manual 23
Identify Times: It indicates the times that the results need to be identified before being output.
You can choose 2, 3, or 4 times.
Identify Threshold Value: It indicates the reliability of identification, which needs to be input
manually.
Identify interval for same plate: It indicates the interval for outputting the identification results
of the same license plate again, which needs to be input manually. The unit is second.
Output one time for plates in same position: It ensures that the identification results for
license plates in the same position (still) are output only once. You can enable this function by
selecting this item.
Virtual coil trigger: When a vehicle enters the virtual coil, the license plate identification result
is output. You can enable this function by selecting this item.
Input one time for same plates: It ensures that the identification results for the same license
plate are output only once. You can enable this function by selecting this item.
Trigger Mode: It indicates the conditions for triggering license plate recognition. You can
choose Video Trigger, Sense Coil Trigger or Mixture Trigger.
Recognition Mode: Choose Single Frame Mode or Multiple Frame Optimization Mode.
Single Frame Mode: It is used to recognize a single picture and then output the result.
Multiple Frame Priority Mode: It is used to recognize multiple pictures and then output the
results.
Upload Mode: It indicates the mode for uploading picture data. Only SDK uploading is
supported.
Output Filter: It indicates the output mode for recognition results. You can choose Full Output,
Filter vehicle far away or Filter vehicle nearby.
System Parameter:
The brake work mode: It indicates the mode for triggering brake opening. You can choose