8 LPRS2000 Hybrid Recognition Integrated Machine User Manual
The default configuration of the reader is as follows:
Work Mode
Read Always
Communication
Interface
Wiegand26
Output Power
33dBm
Working Frequency
UHF 6E Pro: 865MHz ~ 868MHz;
Demo Using Instructions
Connect the USB port of the reader to the USB port of the computer.
The power adapter is recommended to use the DC12V/3A specification. Power supply to reader,
and the buzzer sounds once.
In the computer to open Demo, click “Connect”, on the right side of the middle will show
“Connect Successful”, and machine and demo connection success.
Wiegand Output Time
: Sets the time interval between adjacent wiegand data.
Reader Indicate
: Set whether the buzzer rings when the machine is on the electricity and brush
the card.
Work Mode
: Set the working mode of the machine, and including always read mode, trigger
mode. Under trigger mode, time of reading card can be set when it is triggered once.
RF Setting
: Set the RF parameters of the machine, including power, spectrum. Power range is
10~33dBm.
Wiegand Format
: Set the machine's wiegand output format.
Wiegand Output Settings
: Sets the forward or reverse output of the machine's Wiegand Data,
and start output from the first few bytes.
Tag Reading Interval
: Set the machine to read the card interval. Read card interval is the time when
from the card is read within the scope of the card to the card is left out of the scope of the card to
read the second time card.