G4[QR]
User Manual
P a g e
| 65
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
“C
“denotes the card number; “
E”
denotes the even parity bit; “
O”
denotes the odd parity bit;
“F
“ denotes the facility code; “
M”
denotes the manufacturer code; “
P”
denotes the parity bit; and
“
S”
denotes the site code.
10.5.2
Wiegand Out
On
Wiegand Settings
interface, tap
[Wiegand Out]
to open the Wiegand Out interface.
Function Description
Menu Options
Function Description
Wiegand format
The Wiegand format value could be 26bits, 34bits, 36bits, 37bits, 50bits.
Wiegand out bits
After choosing the Wiegand format, you can select one of the
corresponding output digits in the Wiegand format.
Failed ID
If the verification is failed, the system will send the failed ID to the device
and replace the card number or personnel ID with the new ones.
Site code
It is similar to device ID except that it can be set manually and repeatable
with different devices. The default value ranges from 0 to 256.
Pulse width(us)
The time width represents the changes of the quantity of electric charge
with high-frequency capacitance regularly within a specified time.
Pulse interval(us)
The time interval between pulses.
ID type
Select the ID type as User ID or Card number.