G4[QR]
User Manual
P a g e
| 41
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
Verification Mode
The supported verification mode includes fingerprint/password/face/card, User
ID only, password, face only, and face + password. The default is
fingerprint/password/face/card.
Door Valid Time
Zone
To set time period for door, so that the door is available only during that period.
Normally Open
Time Zone
Scheduled time period for “Normal Open” mode, so that the door is always left
open during this period.
Master device
When setting up the master and slave, the status of the master can be set to exit
on enter.
Exit: The record verified on the host is the exit record.
Enter: The record verified on the host is the entry record.
Auxiliary Input
Configuration
Sets the door unlock time period and auxiliary output type of the auxiliary
terminal device. Auxiliary output types include None, Trigger door open, Trigger
Alarm, Trigger door open and Alarm.
Alarm
The default is Off.
Local Alarm
Transmits a sound alarm or disassembly alarm from the local. When the door is
closed or the verification is successful, the system will cancel the alarm from the
local.
External Alarm
The default is Off.
Reset Access
Settings
The access control reset parameters include door lock delay, door sensor delay,
door sensor type, verification mode, door valid time zone, normally open time
zone, master device, and alarm. However, erased access control data in Data
Mgt. is excluded.
5.2
Time Rules Settings
•
On the
Access Control
interface, tap
Time Rules
to set the Time Rule.
•
The entire system can define up to
50
Time Rules (that is Time Rule1, Time Rule2, …. Time
Rule 50).
•
Each Time Rule represents
7
Time Zones, i.e.
1
week and 3 holidays, and each Time Zone is a
standard 24-hour period per day and the user can only verify within the valid time period.
•
For each Time Zone you can set a maximum of
3
Time Periods. The relationship among
these Time Periods is "or".
•
When the Verification Time falls in any one of these Time Periods, the verification will be
successful and valid.
•
Time Zone format for each Time Period: HH MM-HH MM, accurate to minutes by 24-hour
clock.
•
Tap on the grey box to search for the required
Time Rule
. Enter the required Time Rule set
(that is, search as “Time Rule 1” …” Time Rule 50”).
•
On the
Time Zone
interface, tap on the day (that is Sunday, Monday …) in which the Time
Period needs to be set.
•
On the
Time Period 1
interface, set the Start and End time, and then tap
OK
.