5
Access Settings
The
Access Settings
facilitates to set the access parameters.
5.1
Access Control Options
Access Control Options are used for setting the access parameters.
•
On the
Main
menu, tap
[Access Control].
•
The
Access control
options includes the following functions.
Menu Options
Function Description
Door lock delay
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1~10 seconds; 0 second represents disabling the function.
Gate Mode
Toggle between ON or OFF switch to get into gate mode or not.
When set to ON, on this interface will remove Door lock delay, Door sensor
delay and Door sensor type options.
Door sensor delay
If the door is not locked and is being left open for a certain duration (Door
Sensor Delay), an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door sensor type
There are three Sensor types: Close, Normal Open and Normal Closed.
Close: It means door sensor is not in use.
Normal Open: It means the door is always left opened when electric power is
on.
Normal Closed: It means the door is always left closed when electric power is on.