background image

 

 

 

 

 

1) Meaning of LED indicators: 

POWER indicator (red): light always indicates control panel is power on.   RUN indicator (green): flashing indicates the system works normally. 
COMM1 indicator (yellow): flashing indicates the system is communicating with upper-level devices (for example, the PC).   
COMM2 (yellow): flashing indicates the system is communicating with lower-level devices (for example, readers). 
WLAN indicator (green): flashing indicates the system is communicating in wireless (WIFI) mode.   
DOOR indicator (green): flashing indicates a door opening signal (a door is opened). 

2) Recommended use of wires: 

Interface 

Wire Specification 

Network cable 

Maximum length 

Power (A) 

18AWG*2PIN 

1.5M 

Wiegand (B) 

24AWG*6PIN 

(6PIN, 8PIN, 10PIN for different readers) 

CAT-5 or above network cable, one way 
DC impedance less than 100Ω/KM 

100M 

Electric Lock (C) 

18AWG*2PIN+24AWG*2PIN.

 

18AWG*2PIN for lock connection, 

24AWG*2PIN for door sensor connection. 

50M 

Button (D) 

24AWG*2PIN 

100M 

EXT RS485 (E) 

20AWG*2PIN+24AWG*2PIN, 

20AWG*2PIN for reader power supply, 

24AWG*2PIN for RS485 communication 

CAT-5 or above network cable, one way 
DC impedance less than 100Ω/KM. In 
wire connection, +12V and GND of 
power supply need to be parallel and 
use double wires. 

Share power with control 
panel: 100M 
Use independence power 
supply (connect RS485 signal 
interface only): 1000M 

 

3) The auxiliary input may be connected to infrared body detectors, fire alarms, or smoke detectors. The auxiliary output may be connected to 

alarms, cameras or door bells, etc. 

4) State Indicators are connected to the chassis, with is power indicator, run status indicator and communication status indicator. 
5) PC RS485 indicates the RS485 cable is connected to the PC through this port. The EXT RS485 port can be connected externally to RS485 reader. 
6) The USB slot is primarily used for control panel upgrade. For details, see the user manual. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. LED Indicators and Wire Illustration 

Rotary DIP Switch   

Wiegand Reader 1 

EXT RS485

 

Wiegand Reader 2 

Antenna Connector 

 

Wiegand Reader 4 

Wiegand Reader 3 

PC RS485 

Ethernet/PoE 

Interface 
 

USB 

 

Reset 

Disassembly/

Mains/Battery 

Abnormality 

Alarm 
 

Power 

Input 

Auxiliary 

Input 

Auxiliary 

Output 

#1 Door 

State Indicator 

#2 Door 

Отзывы: