3.2.4 Unlocking Combination settings
Combo settings are for extra added security, where more than ons user need to sign in
before access is granted.
3.2.5 Change Access Control Parameters settings
Summary
* Combo settings for
added security
* 2 or more user verifi ca-
tion needed before access
allowed
* Parameter settings is to
change the control of the
unit
13
•
Press to select UNLOCK COMB SETTINGS
• Press
•
Press (menu) for NEW / EDIT / DELETE op-
tions
•
Press to select ACCESS CONTROL SETTINGS
• Press
•
Press to select fi eld and change values
•
Press
to select ACCESS CONTROL SETTINGS
•
Press
to select field and change values
•
Lock (1-10s) :
To adjust the unlocking time after verifi cation.
•
Dsen. Delay (1-99s) :
To delay door sensor from triggering alarm
system when door is not closing. This function
only works when a door sensor is attached to
the reader.
•
Dsen Mode :
To choose the type of door sensor attached to
the reader. There are NO (normally opened)
and NC (normally closed) available. Choose
NONE if no door sensor is attached.
•
Alarm Delay (1-99s) :
To delay the reader from triggering alarm
system.
•
Alarm count (1-9 ti mes ) :
To adjust the maximum verifi cation failures of
users. When the maximum is reached, reader
will trigger alarm system.
•
Close TZ :
Door is always locked during the predefi ned
time period, so users cannot gain access after
verifi cation.
•
Open TZ :
Door is always unlocked during the predefi ned
time period, so users do not need to verify their
identities but can gain access.
•
Valid holidays :
Choose Valid to enable the holiday settings.
Choose Invalid to disable the holiday settings.
•
Press to save.