NG5-NG7-NG9
English
D01474-16
10
Visualization
V
A
LINE
ALARM
MODE
V A
END CHARGE
ON CHARGE
100%
START
80%
80%
SET
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Description
Equipment
Charging phase indicator
Display
Charging curves set
Ready light
Digital adjustment mode
Mains alimentation alarm
On current production
Optional
Charging Level Indicator
RED LED shows that the battery is in the initial charging phase.
YELLOW LED shows that the battery charger has reached 80% of charge.
GREEN LED shows that the battery has reached 100% of charge.
Further information can be found in the description of the Charging Curve.
Digital Instrument
The Digital Instrument indicates the output tension expressed in Volt (V) and the output current
expressed in Ampère (A).
The corresponding unit of measure of the visualised numbers is indicated by the LED V or A.
By means of the MODE button (when installed),, it is possible to select A or V to be visualised.
N.B. The instrument indicates with three dots ... the output voltages, which are lower to the nominal
value of the battery.
Ready light
The RED LIGHT on shows that charging process (composed by a CHARGING phase and by an eventual
WAITING phase) has been activated.
The GREEN LED lights on from the end of the charge: it indicates the battery is ready to be used.
Line Alarm Indicator
This RED LED turns on in two situations:
1.
one of the 3phases is lacking of input supply circuit (in this situation the battery charger will not
operate and the charging level indicator changes to yellow - check mains and input fuses);
2.
Start/Stop hardware open (in this situation the battery charger will not operate and the charging
level indicator changes to yellow).
100%
START
80%
80%
V
A
MODE
V A
END CHARGE
ON CHARGE
LINE
ALARM