ES3, ES4 & ES6 Instructions. Issue: No. 2 

Page 1  

February / 2012

Contents

Contents

1

Description

2

Approvals

2

Safety information

3

Technical data

5

Parts list

6

Installation

7

      Requirements

7

      Installation site

7

      Installing the appliance

8

      Electrical connection / circuit diagram

11

Commissioning 

12

Maintenance and cleaning 

13

Fault finding

14

Warranty

16

Please read these instructions carefully before commencing installation of the  
InLine Electronic Instantaneous Water Heater.

Please leave these instructions with the end user after installation.

To ensure you have the latest revision of this instruction manual, please visit 
www.zipheaters.co.uk to download the latest copy.

In order to preserve our environment we ask that you dispose of this product 
correctly. 
Please contact Zip Customer Service for advice on 0845 602 4533.

Содержание InLine ES3

Страница 1: ...tructions carefully before commencing installation of the InLine water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham Norfolk...

Страница 2: ...Inside Back Cover Inside Front Cover...

Страница 3: ...ning 13 Fault finding 14 Warranty 16 Please read these instructions carefully before commencing installation of the InLine Electronic Instantaneous Water Heater Please leave these instructions with th...

Страница 4: ...ower temperature is required If the flow rate is too low or if the hot water tap is closed the appliance switches itself off automatically For an optimum flow of water always fit the special jet regul...

Страница 5: ...nction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by Zip Heaters UK Ltd or an authorised Zip service engineer Temperatures in...

Страница 6: ...must be vented by opening and closing the hot water tap until all air has been eliminated from the water heater and no more air emerges before re connecting to the electrical supply The appliance must...

Страница 7: ...on flow rate l min 1 2 1 5 1 5 Switch off flow rate l min 1 0 1 3 1 3 Minimum differential pressure factory set flow rate 0 025 MPa 0 25 bar 0 05 MPa 0 50 bar 0 075 MPa 0 75 bar Factory set temperatur...

Страница 8: ...ll bracket only 4 IN80353 Set of small spare parts seals nozzle for cable entry etc 5 IN80080 Filter sieve fine filter 6 IN80750 Water connection set including two water connections and seals 7 IN8037...

Страница 9: ...ectional area of the connection cable must be in accordance with the power rating of the appliance and the specific requirements of the installation site Take care to protect the wiring from damage du...

Страница 10: ...an be checked with the local water supply company Thoroughly flush the water supply pipes before installation to remove any water borne debris Installing the appliance 1 Secure the wall bracket to the...

Страница 11: ...ipe connectors Fig 3 2 When supplying mixer taps a non return valve must be fitted to the hot water outlet and not to the cold water inlet fig 5 3 A flow control valve may be required on the cold supp...

Страница 12: ...4 5 show unvented installation with closed outlet tap Fig 4a shows open vented installation Fig 4 You may also use an open vented installation 187mm 132mm Fig 5 Service Valve Flow Control Valve Mains...

Страница 13: ...rity requirements Important The appliance must be installed according to the specification on the rating plate and the technical specifications Ensure that the voltage marked on the appliance matches...

Страница 14: ...eved Water too cold Increase the temperature by turning the potentiometer counter clockwise until the desired temperature is achieved If the desired temperature cannot be achieved the red LED on the P...

Страница 15: ...cleaned at regular intervals Rinse the regulator with water and brush off the debris For difficult to remove deposits soak in white vinegar or a proprietary scale cleaner for a few minutes and scrub w...

Страница 16: ...lve shut off valve Water flows more slowly than expected The Jet Regulator is not fitted Fit the correct Jet Regulator see Fig 5 Water pressure is not sufficient Check the water flow pressure check th...

Страница 17: ...incorrect Check the electric supply Circuit breaker has tripped Safety thermal cut out has tripped Have the fault rectified by a technician and reset the circuit breaker thermal cut out Hot water tem...

Страница 18: ...ent of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any ot...