801910 - Zip Sparkling HydroTap - Installation Instructions - July 2014 - V1.00
Page 25 of 40
Section 4
Filter / Softener Installation
An external filter / Softener may be fitted to reduce the incidence of scale build up in the hot tank or may be
supplied at the customer’s request.
•
Choose a suitable location, (cupboard back or side wall)
within the reach of the braided hoses.
•
Mount the filter head bracket in an upright position, using the
screws supplied in the kit
•
Ensure there is enough headroom for the filter cartridge to be
easily fitted and removed. *Allow a Min 80mm base clearance
•
Attach the hoses as shown in section 5.5 - 5.7. Noting the flow
directions as marked on the filter head.
4.1
Mounting the filter head
*Min. 80mm
Clearance
4.2
Cartridge Installation
1.
Unpack replacement cartridge, write today’s date where
shown on the label and remove the sanitary cap.
2.
Avoid touching the filter O-rings and filter opening as this may
cause bacterial contamination of the cartridge.
3.
Moisten the O-rings with water, align the front cartridge label
to the left and push the new cartridge into the filter head.
4.
Turn the cartridge a quarter turn to the right until the cartridge
comes to a complete stop, with the front label facing forward.
5.
Disconnect the filter outlet hose from the underbench unit and
direct the hose end into a container ready for flushing.
6.
Depress Boiling lever on the tap and allow water to run for 30
seconds.
7.
Water will now run through the filter.
8.
Allow 10L to flow through the filter to ensure all carbon
particles have been flushed.
9.
Turn the water off at the mains supply once 10L have been
achieved.
10.
Reconnect the filter outlet hose to the underbench unit.
11.
Turn the mains supply back on and check for leaks.
12.
Set the appropriate selection on the Internal Filter Bypass
valve located at the rear of the unit in accordance with
Sections 5.1 and 5.2.
Filter Label
Inlet
Outlet