background image

Page 4 of 20

Zip HydroTap Installation and Operating Instructions - 82872 - July 2003

Read These Warnings First

Safety

Do not allow young children, handicapped or infirm persons, to use the Zip
HydroTap without supervision 

Refrigerant

The Zip HydroTap Chilling unit contains 134A refrigerant under pressure. No
part of the unit should be exposed to a naked flame. Maintenance of
refrigeration unit must be carried out by an accredited service provider or
qualified refrigeration mechanic.

Qualifications

If any power cord or plug is damaged it must be repaired only by a
qualified technician.

To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson.

Venting

Sometimes steam and/or boiling water may discharge through the vent at
the rear of the tap shank. If the tap is not installed on a sink, the pipe to
this outlet must be disconnected and plumbed away to a safe location
according to local plumbing bylaws and regulations.

Lifting

Take care when lifting the Zip HydroTap undersink unit. Some units may
exceed safe lifting limits. Do not lift without assistance. The weights of the
units are given in the table under Installation Requirements (page 5).

Airflow

Proper air circulation must be provided. The system will operate
satisfactorily only if the recommended air gaps are provided. If this is not
possible, ventilation slots must be cut into the top AND bottom of the
cupboard door. Make sure that the ventilation grilles of the undersink unit
are not obstructed.

Altitude

At altitudes over 500 metres above sea level, the thermostat temperature
may require adjustment. Contact your Zip Service Provider.

Filter

For models ABC, ABA and ABB only:

The Zip HydroTap filter timer is preset to nine months to provide trouble-
free flow and operation in most installations. Local water quality conditions
may require an alteration to this time. In areas where the water has a high
concentration of sediment, the preset time may be shortened to avoid poor
flow, taste or odour situations. In areas where the water quality is above
average, lengthening the preset time may be desirable, but not essential.

If any of these changes are needed, contact your Zip Service Provider.

Содержание HydroTap ABC10/30FXC

Страница 1: ...73078 Zip HydroTap ABC10 30FXC 73119 Zip HydroTap ABC30 30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC 73110 Zip HydroTap B1OC 7...

Страница 2: ...Page 2 of 20 Zip HydroTap Installation and Operating Instructions 82872 July 2003...

Страница 3: ...lling the undersink unit all models 7 Step C Connecting the tap 7 Installation with Tap Font 8 Tap Font Mounting Template a d Installation procedure Continued 13 Step C Connecting The Tap continued 13...

Страница 4: ...he Zip HydroTap undersink unit Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table under Installation Requirements page 5 Airflow P...

Страница 5: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed A water supply which can deliver 2 litres per minute flow rate at minimum of 1 5 Bar 150...

Страница 6: ...that the tap will be able to drain into the sink Mark the two hole centres and cut the small hole using a 13 5 mm sheet metal hole punch Cut the large hole using a 35 mm sheet metal hole punch Install...

Страница 7: ...bottom of the cupboard door Make sure that ventilation grilles are not obstructed Allow access to water inlet located on the left hand side of undersink unit Step C Connecting the tap Model ABC Mount...

Страница 8: ...pedestal is positioned above largest hole in bench Pass all cables and tubes from pedestal through largest hole in bench Fit clamp spacer and lock nut on to drain bush and tighten securely Clean off...

Страница 9: ...Zip HydroTap Installation and Operating Instructions 82872 July 2003 Page a Detach this papertemplate and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Страница 10: ...80 mm 45 mm MINIMUM CLEARANCE FROM REAR WALL CIRCUMFERENCE OF TAP FONT BASE SMALL HOLE SCREW HOLE SCREW HOLE...

Страница 11: ...57 mm SCREW HOLE SCREW HOLE LARGE HOLE...

Страница 12: ...Page d Zip HydroTap Installation and Operating Instructions 82872 July 2003 Detach this paper template and use it to position your Zip Hydrotap Tap Font on your kitchen bench...

Страница 13: ...gs vertically Model B Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit Measure and trim the unmarked tube and connect it to the vent outlet...

Страница 14: ...the Fill switch to the On down position The water will stop flowing For Model ABC press and hold the blue button for about 1 minute after water begins to flow Check that the lamps operate according t...

Страница 15: ...provider The red lamp flashes once a second There is a problem with the Turn off the power and the water when the water is hot undersink unit and call your Zip service provider The boiling water is ru...

Страница 16: ...s a leak in the undersink water system and the unit will be shut down In this case call Zip services Filter Change Light Flashing slowly once every minute The light will flash once every minute when t...

Страница 17: ...ch it from the filter head socket 4 Do not tilt the cartridge as dirty water may spill from it if tilted 5 Unpack replacement cartridge and write today s date where shown on the label 6 Avoid bacteria...

Страница 18: ...selected Press and release button m until correct minute is selected When day hour and minute are correct release button Programming Power ON OFF 1 Press and release the Prog button once 2 Display wil...

Страница 19: ...returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No w...

Страница 20: ...gistered trade marks Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US509...

Отзывы: