Note. This device must be installed vertically with the direction of flow
downwards (inlet at the top , outlet at the bottom. See Fig 1 adjacent).
•
The Water Block should be installed in a convenient location on the water
supply line to the Zip product.
• Pointer ‘P’ (see Fig.3) should be rotated until in line with the maximum required flow at
one time. Each number on the scale corresponds to 5 litres of flow i.e. 1 = 5 litres, 10 = 50
litres.
• The adjustment key (see Fig.2) should be used to adjust the pointer.
• The inlet should be connected via an 15mm isolation valve (not supplied).
• The outlet shall be connected via the 15mm - 1/2” brass compression fitting supplied.
• Ensure that the direction of flow through the Water Block is correct and that the filter
screen (see Fig.2) is inserted correctly with the convex surface facing towards the water
supply.
1.2 Installation
Fig. 2
Fit key to adjust flow
Key
Reset lever
1.3 Reset Procedure
• The Water Block will activate and shut off the supply if more water than the set amount is drawn off at one time.
• In this event firstly isolate and de-pressurise the water supply to the Water Block, identify and repair the cause of
the leak then remove the pipe-work downstream of the Water Block and press the reset button ‘H’ (see Fig.3).
• The reset device (see Fig.2) may be fitted to avoid disconnection. This allows the Water Block to be reset by
operating the lever in the direction shown in Fig.2.
• In the event of persistent tripping contact Zip for advice on 0345 6 005 005.
1.4 Maintenance
• The filter screen should be checked and cleaned periodically subject to water conditions and usage.