15
Installation instructions & user manual
806310UK V1.00 July 2019 - HydroChill HC05
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Condenser
•
The condenser should be cleaned at regular 12-monthly intervals, or when
the filter is replaced.
•
The condenser is accessed by a removable panel in the side of the external
case. Disconnect power and remove the 4 screws holding the panel in place
, see adjacent diagram.
•
Remove the panel and clean the condenser using a soft-bristled brush or
vacuum. Replace the panel and restore power when complete.
Leak Detector
•
A Leak Detector is built into the appliance. If activated, water flow will stop.
•
Remove the front panel of the appliance to access the leak detector,
located towards the front of the unit at its base. Identify and repair any
leaks. The leak detector pad must then be replaced.
•
Open the cover of the leak detector, (see adjacent diagram). Remove the
existing pad and replace with a new pad. Close the cover and check that
water flow has returned.
•
Replace the appliance panel.
Maintenance