background image

18

Installation instructions & user manual

 

T210029 v2.01 Dec 2020 - ZIP HC03CTU15

Technical support 

 

Tel: 0345 6 005 005 email: aftersales@zipindustries .co.uk  www.zipwater.co.uk

Installation 

Connect the mains electricity supply

Connection

• 

Connect the power cable supplied to the IEC 
inlet (1) and a 230V 50Hz 13A mains socket. 

Set the thermostat

Lower the  

water  

temperature

Raise the  

water  

temperature

1

!

Read and understand the generic 
installation warnings and precautions 
before starting this operation 
 

(see page 4)

Содержание HC03CTU15

Страница 1: ...210029 v2 01 Dec 2020 ZIP HC03CTU15 Technical support Tel 0345 6 005 005 email aftersales zipindustries co uk www zipwater co uk Zip Water dispenser Installation instructions user manual Modelnumber HC03CTU15 HC03CTU15TF Chilledandambientwater ...

Страница 2: ...ilter 9 Ventilation 9 The Install rail 10 The water block 11 Technical features 13 Feature identification 13 Rating plate 13 Dimensions 14 Technical data table 14 UV filtration 15 INSTALLATION 16 Unpacking positioning 16 Connecting the mains water supply drain 17 Connecting the mains electricity supply 18 Set the thermostat 18 COMMISSIONING 19 OPERATION 20 MAINTENANCE 22 Replacing the carbon block...

Страница 3: ...isconnect the electrical power supply either by removing the mains plug or via a double pole isolation switch with a contact separation of at least 3mm in all poles Ensure that the water dispenser is not resting on the power cable Do not position other electrical equipment in the immediate vicinity of the water dispenser Do not use electrical extension leads or adapters Turn off the mains power su...

Страница 4: ...rmation available at release It may be subject to change due to continual improvements visit www zipwater co uk for the latest version GENERIC SAFETY INFORMATION SPECIFIC INSTALLATION SAFETY INFORMATION Installation must be carried out by a qualified Zip Water engineer or other suitably qualified person Only install in compliance with the local authority electrical and plumbing regulations Install...

Страница 5: ...t Always use a new set of fittings connectors gaskets o rings and pipes for the installation Previously used fittings may affect the water quality UV Precautions Sanitising For safe operation the water dispenser is designed to be installed commissioned and used within 48 hours Should the water dispenser not be required for an extended period of time 48 hours or more do not fill and commission it u...

Страница 6: ...ct the electrical power supply and isolate the water supply The light emitted by the ultraviolet lamp may cause serious burns to the eyes and skin Installation repair and maintenance shall only be performed by personnel qualified to work on UV products Apart from the carbon block filter there are no user serviceable parts in the water dispenser The water dispenser requires regular periodic mainten...

Страница 7: ...ner if you notice a persistent reduction in water flow from the tap or an unpleasant taste or odour in the water As stated on the filter cartridge For safe operation thoroughly flush the water dispenser after periods of non use longer than 48 hours Not changing the filter cartridges when required may affect the water quality Sanitisation should be carried out at all filter changes at least at inte...

Страница 8: ...e of the art technology and cutting edge design The main features of the water dispenser are as follows Chilled and ambient water dispense Modern compact design Carbon block filter Ease of maintenance and usability Drip tray full and leakage alarm Suitable to fill sport bottles and carafes Illuminated dispensing area High position buttons UV filtration on dispense outlet Touch free controls TF mod...

Страница 9: ...e The filtration system Is an integral part of the water dispenser Uses an activated carbon filtering material Complies with NSF ANSI 42 for the reduction of the following substances Substance Max concentration in feed Min removal required Min reduction Average reduction Free chlorine 2 0mg L 10 50 97 6 97 3 100mm 100mm 100mm Clearance envelope A clearance envelope around the water dispenser must ...

Страница 10: ...rts The isolation valve isolates the mains water supply from the water dispenser for servicing The Pressure limiting valve PLV rated at 16 bar allows the water dispenser to be used in high pressure water areas and limits the inlet supply to a maximum of 3 bar pressure The Water Block minimises the risks involved in the unlikely incidence of flooding see Water Block section page 11 for detailed exp...

Страница 11: ...will ensure that the volume of water that can flow through at one time is limited to a predetermined maximum providing the flow rate through it exceeds 2 litres per minute The Water Block also incorporates a non return valve The Water Block is WRAS approved Precautions The Water Block will help to contain leakage exceeding a rate of 2 l min Note The leakage at lower flow rates may not be detected ...

Страница 12: ...ction of flow through the Water Block is correct and that the filter screen see Fig 2 is inserted correctly with the convex surface facing towards the water supply Installation Fig 2 Fit key to adjust flow Key Reset lever Reset maintenance The Water Block will activate and shut off the supply if more water than the set amount is drawn off at one time In this event firstly isolate and de pressurise...

Страница 13: ...E ONLY WHOLESOME WATER S N 1906094341 Power rating Current rating Climate class Country of origin Water supply requirements Conformity to EU product directives UK product regulations Supply voltage Refrigerant gas type weight Unique product serial number Conformity to EU environmental directives Feature identification 8 9 Electrical power inlet Ø1 4 water inlet pipe 1 Electrical power switch 2 Rat...

Страница 14: ... 230W 1 A Ambient running temperature 10 32 C Refrigerant gas R600 Ventilated air condenser YES UV sterlising lamp wavelength 254nm Chilled water temperature Min Max 5 12 C Operating pressure 1 5 3 0 bar Refrigerant capacity 15 Lt h Compressor capacity 1 10 HP Cooling tank capacity 2 75 Lt Net weight max 21 1 Kg Gross weight max 23 8 Kg Dispensing area height 280 mm Dimensions W x D x H 345 x 416 ...

Страница 15: ...ntegral carbon block filter The UV C light emitted by the special 4W mercury vapour lamp is lethal for all micro organisms bacteria viruses mould algae etc and is used in order to render the water treated with the UV C light micro biologically pure and safe Technical data Material AISI 304 and quartz tube Power rating 24 V AC Power consumption 4Wh Maximum capacity of the lamp 8000 hr max 12 months...

Страница 16: ...d it vertically then wait at least 24 hours before use in order to allow the refrigerant to settle Read and understand the specific installation warning and precautions before starting this operation see page 4 Positioning Place on a flat level and stable surface sufficient to support the weight of the water dispenser when full see data table page 14 Observe the clearance envelope see page 9 Elect...

Страница 17: ...h incoming mains water pressure to 3 bar 0 3 MPa The install rail supplied see page 10 must be fitted Ensure that the isolation valve on the install rail is closed see page 10 Connect incoming water tube Ø1 4 1 to the Install rail see page 10 To connect the drip tray to drain optional remove the drip tray 2 drill out the blanked off drain boss 3 using a Ø6mm bit Connect a pipe onto the drain boss ...

Страница 18: ...www zipwater co uk Installation Connect the mains electricity supply Connection Connect the power cable supplied to the IEC inlet 1 and a 230V 50Hz 13A mains socket Set the thermostat Lower the water temperature Raise the water temperature 1 Read and understand the generic installation warnings and precautions before starting this operation see page 4 ...

Страница 19: ...48 hours Zip recommend a system flush be performed On first use after a period of non use run the chilled ambient water functions for 60 seconds to flush the filter and system Not flushing the system may affect the water quality If taste or water quality issues persist a filter change and sanitisation may be required Check that all pipes and fittings are connected properly Check the external pipe ...

Страница 20: ...tersales zipindustries co uk www zipwater co uk HC03CTU15 Operation P1 P2 DRIP TRAY FULL L1 L1 P1 P2 Drip tray full indicator Illuminates when the drip tray is full Empty the drip tray to extinguish Chilled water Press to dispense Ambient water Press to dispense HC03CTU15TF Operation TOUCH FREE DRIP TRAY FULL L1 L2 L3 S1 S2 ...

Страница 21: ...around 15mm 1 5 cm There is a 1 second delay before activation of the dispensing function and the LED for the selected type of water turns itself off The water continues to be dispensed for as long as your finger remains in position in front of the sensor Move your finger away to stop the dispensing operation On deactivation of the dispensing function the LED for the selected type of water turns i...

Страница 22: ...il free then pull it down discard responsibly Remove the protection cap wrapper from the new filter cartridge see 2 below Insert the cartridge aligning the open lock symbol on the filter head with that of the cartridge see 3 below Push the cartridge upwards until it engages then turn anti clockwise until it clicks into place see 4 5 below Filter flush Disconnect the flexible pipe from the filter o...

Страница 23: ...d cap from the drain pipe 1 located in the filter compartment Press the chilled water dispense buttons Drain the contents of the cold tank through the tank drain connection 1 into the bucket The capacity of the system is approximately 2 7 litres of water Replace the end cap on the drain pipe front cover 1 General cleaning Dispense 10 litres of water to flush out any carbon residuals from the new f...

Страница 24: ...low rate is low Blocked filter Change filter Low inlet water pressure Contact the Zip Water team Chilled water is not cold Thermostat setting Lower the thermostat set point Rear vent grille blocked Brush clean to allow ventilation Clearance envelope not observed Maintain proper clearances see page 9 Fault finding table Leak indicator If there is a water leak sufficient to cover the leak detector p...

Страница 25: ...ut wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical and electronic equipment In order to preserve our environment we ask that you dispose of this product correctly Please contact the Zip Water team for advic...

Страница 26: ...to accident misuse abuse unsuitable water conditions including contaminants or inappropriate water pressure or to any alteration modification or repair by any party not expressly nominated by Zip 2 This warranty does not cover damage resulting from non operation of the product or consequential damage to any other goods furnishings or property 3 This warranty does not apply to any consumables 4 Zip...

Страница 27: ...27 Installation instructions user manual T210029 v2 01 Dec 2020 ZIP HC03CTU15 Technical support Tel 0345 6 005 005 email aftersales zipindustries co uk www zipwater co uk Notes ...

Страница 28: ...10029 v2 01 Dec 2020 ZIP HC03CTU15 Technical support Tel 0345 6 005 005 email aftersales zipindustries co uk www zipwater co uk ZipWater TrafalgarHouse Rash sGreen Dereham Norfolk NR191JG 03456005005 sales zipindustries co uk www zipwater co uk ...