Connect the power supply and turn on.
The compressor and fan will start, and the water pump will operate for
approximately 20 seconds to fill the carbonator vessel.
After approximately 5 minutes, the compressor and fan will stop as the chiller
has reached its normal operating temperature.
To achieve an optimal level of carbonation, it is beneficial to purge the
carbonation vessel again by isolating the water and electrical supply, and
opening the sparkling lever on the tap until gas is expelled for approximately 5
seconds. Close the tap and reconnect water and power. Wait 20 seconds and
the sparkling water should be ready for use.
At this time check to ensure the pressure gauge is still reading 2.7 bar. If not,
adjust the regulator accordingly.
Important
: Excessive flow rates of carbonated water will result in poor drink
quality. It is recommended that the flow rate for carbonated water should be
approximately 1.2 - 1.8 litres/minute. If this is incorrect, it must be adjusted by
a qualified service technician.
Ensure there is adequate ventilation available through the cupboard. If there is
inadequate ventilation, and the cupboard temperature rises to above 40°C, the
chiller may be damaged and malfunction which will void the product warranty.
The air temperature should be no more than 35°C.
There must be a minimum 168cm² of cupboard cross-flow ventilation. Suitable
holes or vents will need to be cut into the cupboard and door.
For safe operation, thoroughly flush the water through after non-use periods
longer than 24 hours.
Operation:
The lever on the right (Blue rings) is used for chilled still filtered water and the
lever on the left (White rings) is used for chilled sparkling filtered water.
Chilled water is obtained by rotating the lever on the right, to a horizontal
position. The water is chilled by a refrigeration unit fitted within the cabinet
stand, under the basin.
With the carafe tap, you can obtain chilled water within the rated capacity, for
as long as you leave the lever in the open (horizontal) position. When finished,
return the lever to the OFF (upright) position.
Sparkling water is obtained in the same way as the chilled water, by rotating
the lever on the left hand side of the carafe tap.
NOTE
: After dispensing sparkling water, a small amount will remain in the
carafe filler. If the next drink is to be still water and you do not wish any
trace of sparkling water, the still water should be running for approximately 1
second before filling your glass or bottle. The same is applicable if still water is
dispensed prior to dispensing sparkling water.
Filter Replacement
For safe operation, the filter cartridge should be replaced every 6-12 months, or
earlier if you notice a persistent reduction in water pressure from the appliance
or an unpleasant taste or odour in the water.
Chilled filtered water
(blue)
Sparkling filtered water
(white)
Operating Procedures