Zip ChillTap Sparkling DOMCTS Скачать руководство пользователя страница 1

Installation & Operating Instructions - 801957UK_DOMCTS- Zip ChillTap Sparkling - June 2014 V2.01 

Page 1 of 14

Installation and Operating Instructions

Zip ChillTap Sparkling DOMCTS

  

Undersink filtered / unfiltered chilled drinking water

®

Filtered chilled still and chilled sparkling water

Affix Model Number Label Here

801957UK DOMCTS

GP

Содержание ChillTap Sparkling DOMCTS

Страница 1: ...ap Sparkling June 2014 V2 01 Page 1 of 14 Installation and Operating Instructions Zip ChillTap Sparkling DOMCTS Undersink filtered unfiltered chilled drinking water Filtered chilled still and chilled sparkling water Affix Model Number Label Here 801957UK DOMCTS GP ...

Страница 2: ...t of the kit D Check the water quality to determine if extra filtration will be required A potable mains water supply must be used E Check the appliance rating plate and ensure correct power is available for the appliance F Check the underbench cupboard supporting the appliance is adequate for the total weight of the appliance Read all instructions and precautions before proceeding If in doubt or ...

Страница 3: ... of the power supply cable must be appropriate for the power rating and location of the appliance The power supply cable must be adequately secured Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply Take care when lifting the Zip ChillTap unit Some units may exceed safe lifting limits If you feel this is beyond your personal...

Страница 4: ...ore disposal Do not expose to naked flame or any incandescent material Keep out of reach of children High concentration of gas may cause asphyxiation Use only in ventilated areas Use only in an upright position This bottle must be used with the approved pressure regulator Avoid shock Total Rating 0 14kW 230V AC Delivery Temperature Chilled 3 6 C Except under free flow conditions Sparkling 3 6 C Ex...

Страница 5: ... where there is a minimum 52mm wide flat area within the draining area of the sink Make sure the selected position allows the carafe filler spout to overhang the sink bowl Use a 25mm sheet metal punch to create a neat hole without burrs Remove the large nut with the stainless steel and rubber washers from the base of the carafe filler leaving the rubber sealing ring o ring in place Fit the carafe ...

Страница 6: ...cessible for servicing purposes Step C Installing the Filter Position the filter and filter head on the inside of a cupboard wall in a convenient position as close to the unit as possible but still allowing access to change the filter The filter head must be fastened to the cupboard wall in a position high enough to allow the removal and replacement of the filter cartridge Connect a length of John...

Страница 7: ...rst depressing the collet and simultaneously pulling out the plug Measure and trim the 1 4 blue tube from the carafe tap to the JG fitting marked Still Outlet on the top rear of the chiller unit Before making connection insulate the tube with the loose length of the pipe insulation trim the insulation pipe to correct length which is about 10mm shorter than blue tube Push the blue tube fully into t...

Страница 8: ...on Once satisfied that there are no leaks and with the regulator set at 0 27 MPa 2 7 bar refit the gas bottle to the Velcro strap and secure the bottle NOTE Care must be taken when working with high pressure carbon dioxide and in no cases should the normal operating pressure of 0 27 MPa 2 7 bar be exceeded WARNING A gas cylinder containing 1kg of CO2 should be installed in a well ventilated area o...

Страница 9: ... should be no more than 35 C There must be a minimum 168cm of cupboard cross flow ventilation Suitable holes or vents will need to be cut into the cupboard and door For safe operation thoroughly flush the water through after non use periods longer than 24 hours Operation The lever on the right Blue rings is used for chilled still filtered water and the lever on the left White rings is used for chi...

Страница 10: ...e filter system and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow Gas Bottle Replacement 1 Turn off the water and power supply to the chilled sparkling unit 2 Turn off the regulator on top of the bottle The regulator has a left hand thread to turn off turn anti clockwise until shut 3 Remove the CO2 bottle from its mounting and unscrew fro...

Страница 11: ...CO2 bottle Regulator to be set to 0 27 MPa 0 27 bar Internal fault Service Technician Contact local Zip Service Provider Poor levels of carbonation in drinks Incorrect CO2 pressure User Check CO2 regulator Supply pressure should be 0 27 MPa 2 7 bar adjust or replace as necessary Air in carbonation can User Purge system as described on page 9 Gas Bottle Replacement Residue in carbonation can Servic...

Страница 12: ...e empty do not dispose of with general household waste but take to your local recycling centre Contact Zip Customer Service for advice on 0845 6 005 005 if further guidance is required End of Life Disposal Cleaning Do not use strong corrosive spray or abrasive cleaners chemicals Clean the casing tapware external filter piping and all other fittings with a soft cloth and mild soap and water Do not ...

Страница 13: ...Installation Operating Instructions 801957UK_DOMCTS Zip ChillTap Sparkling June 2014 V 2 01 Page 13 of 14 Notes ...

Страница 14: ...ceProviderorthecostofremoval cartageandre installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge instal...