background image

81507 - Zip Freestanding Chilled Water Systems - Installation & Operating Instructions -  April 2015 v2.03 

Page 2 of 8

Read These Warnings First

Finished height will vary due to adjustable feet (Chillmaster only). The average height for the centre line of the plumbing 
services is 790 mm.

Place the unit on a level floor and screw the feet in or out as appropriate to make the unit level and steady (Chillmaster 
only), see Fig.1. 

Leave at least a 50 mm gap between the 
sides of the unit and any walls, to allow 
air flow through the vents. 

The rear of the unit can be flush 
mounted against the surface of a wall if 
the plumbing permits.

Connect only to cold water 10-38°C with 
a pressure range of 70 kPa - 700 kPa.

•       Please read all installation requirements, installation procedures and precautions before installing 

any Zip Chillmaster/Sitemaster/Economaster.

•       Never attempt to install any Zip Chillmaster/Sitemaster/Economaster without reading all of the 

applicable instructions. 

•       All electrical connections must comply with current wiring rules.

•       These appliances ares not intended for use by persons (Including Children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 
use of the appliances by a person responsible for their safety.

•       Children should be supervised to ensure they do not play with the appliances

•       This appliance must be earthed. 

•       If the power supply cord is damaged it must be replaced by a Zip Service Provider or a qualified electrician. 

•       The power cord and GPO must be in a safe and accessible position after installation

•       Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the 

power supply. 

•       The units are for indoor use only and must not be exposed to the elements of nature.

•       These units must not be positioned in an area that may be cleaned by a water jet and must not be cleaned by a 

water jet.

Chillmaster only

Installation Instructions

Fig.1

105

170

Содержание 81507

Страница 1: ...standing Chilled Water Systems Installation Operating Instructions April 2015 v2 03 Page 1 of 8 Installation and Operating Instructions Zip Freestanding Chilled Water Systems Affix Model Number Label...

Страница 2: ...ter without reading all of the applicable instructions All electrical connections must comply with current wiring rules These appliances ares not intended for use by persons Including Children with re...

Страница 3: ...chiller where shown in the diagram Connect a drain to the 40 mm PVC female outlet at the back Alternatively there are pre punched holes in the base of the Chillmaster for bottom access to plumbing ser...

Страница 4: ...to the upright position see Fig 4 Filter Replacement Chillmaster only Your Zip Chillmaster has a filter replacement reminder light that shows through the front label The 2 AAA reminder light batteries...

Страница 5: ...rrectly Please contact your local city council for collection centre details End of Life Disposal Problem Cause Remedy No water at outlets Water not connected Connect and turn on water Water not chill...

Страница 6: ...x Permissible Product Water Concentration Australian New Zealand AS NZS Standard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2...

Страница 7: ...ermissible Product Water Concentration Australian New Zealand AS NZS Standard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2 0...

Страница 8: ...gham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of...