Zip 81507 Скачать руководство пользователя страница 3

81507 - Zip Freestanding Chilled Water Systems - Installation & Operating Instructions -  April 2015 v2.03 

Page 3 of 8

Zip Sitemaster and Economaster

It is the installers responsibility to ensure the installation complies with AS/NZS3500.1, AS/NZS3500.2, AS/NZS3500.4.1, 
AS/NZS3500.4.2 and local water authority regulations. 

Minimum operating pressure is 172 kPa. Where pressure may exceed 700 kPa, a pressure limiting valve must be installed.

No valves are supplied with the product. All necessary valves must be supplied separately by the installer.

Connect a cold water supply to the half inch BSP female inlet at the back of the chiller where shown in the diagram on 
page 3.

Connect a drain to the 40mm PVC female outlet at the back.

Purge the air from the unit when the plumbing connections are complete, by turning ‘on’ the water supply, and pressing the 
button on the bubbler, until the water flows through without spluttering. Check connections for leaks and repair any found.

Zip Chillmaster

Connect a cold water supply to the half inch BSP female inlet at the back of the chiller where shown in the diagram.

Connect a drain to the 40 mm PVC female outlet at the back.

Alternatively, there are pre-punched holes in the base of the Chillmaster for bottom access to plumbing services.

All valves necessary for use with the Chillmaster are already fitted within the unit. This appliance incorporates backflow 
protection complying with AS3500.1. No further backflow protection is required for connection to the water supply. A special 
surge protection system is totally self contained within the Chillmaster, to protect it from damage.

DO NOT ADJUST, ALTER OR REMOVE THE VALVE ASSEMBLY.

Purge the air from the unit when the plumbing connections are complete by turning ‘ON’ the water supply and pressing the 
button on the bubbler until the water flows through without spluttering. 

Electrical

A 1.8m flexible cable and 240v 50 Hz 3 pin plug are fitted. Run the cable out of harm’s way and plug it into a standard 
power point.

Do not turn the power point ‘on’ until the unit is purged.

Installation Instructions 

continued

Operating Procedures

Fig.2

Operating the Bubbler  (All models)

Chilled water is obtained momentarily by pressing the bubbler button, see 
Fig.2.

The water is chilled by a refrigeration unit fitted within the cabinet stand, under 
the basin.

Содержание 81507

Страница 1: ...standing Chilled Water Systems Installation Operating Instructions April 2015 v2 03 Page 1 of 8 Installation and Operating Instructions Zip Freestanding Chilled Water Systems Affix Model Number Label...

Страница 2: ...ter without reading all of the applicable instructions All electrical connections must comply with current wiring rules These appliances ares not intended for use by persons Including Children with re...

Страница 3: ...chiller where shown in the diagram Connect a drain to the 40 mm PVC female outlet at the back Alternatively there are pre punched holes in the base of the Chillmaster for bottom access to plumbing ser...

Страница 4: ...to the upright position see Fig 4 Filter Replacement Chillmaster only Your Zip Chillmaster has a filter replacement reminder light that shows through the front label The 2 AAA reminder light batteries...

Страница 5: ...rrectly Please contact your local city council for collection centre details End of Life Disposal Problem Cause Remedy No water at outlets Water not connected Connect and turn on water Water not chill...

Страница 6: ...x Permissible Product Water Concentration Australian New Zealand AS NZS Standard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2...

Страница 7: ...ermissible Product Water Concentration Australian New Zealand AS NZS Standard 3497 Max Permissible Prod uct Water Concentration NSF Reduction Require ments NSF Test Report Chlorine Taste and Odor 2 0...

Страница 8: ...gham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of...

Отзывы: