background image

17

Installation instructions & user manual

 

9120-34379 v1.20 Okt 2022 - ZIP DCX Next

Technical support 

 

Tel: 0345 6 005 005 email: [email protected]  www.zipwater.co.uk

Check that the power supply is switched off prior to electrical connection!

1 .  Open the prepared breaking point (S) in the upper part of the appliance by pressing 

with a blunt implement (e .g . srewdriver) . For surface-mounted connection cable 

additional open the breakout at the right side of the bottom part .

2 .  Slit the grommet of the accessory set to match the cable size . The opening in the 

grommet should be slightly smaller than the cross-section of the cable in order to 

ensure optimum protection against water . Fit the grommet into the opening . 

The 

protection grommet must be used!

3 .  Strip the connection cable so that the sheath extends through the grommet into 

the appliance . Hold the prepared appliance so that you can route the cable into the 

grommet with the other hand .

4 .  Place the appliance on the wall bracket so that the threaded rod of the wall bracket 

fits in the corresponding hole of the appliance and fix it with the knurled nut .

5 .  Unscrew the fastening screw of the connecting terminal . Displace the connecting 

terminal to the upper foot . Affix the connecting terminal again .

6 .  Strip the individual wires of the connecting cable and plug them in the connecting 

terminals according to the wiring diagram . 

The appliance must be earthed.

Note: To ensure IP25 protection class, please don´t remove the bottom water splash 

protection sleeve. 

6. Electrical connection

Note: If necessary, the connecting terminal can be displaced to the upper part of the 

appliance. If you want to do so, please follow the instructions in the next chapter.
Check that the power supply is switched off prior to electrical connection!

1 .  Dismantle approximately 6 cm off the connecting cable above the wall outlet . With 

the smaller opening ahead, slide the water splash protection sleeve over the con-

necting cable so that the sleeve is flush with the wall . This prevents any leaking 

water from coming into contact with the electrical leads . It must not become dam-

aged! 

The protection sleeve must be used!

2 .  Strip the individual wires and plug them in the connecting terminals according to 

the wiring diagram . 

The appliance must be earthed. 

3 .  Pull the protective sleeve so far over the connecting cables and shape the connect-

ing cables in such a way that the sleeve fits perfectly in the recess of the intermedi-

ate panel without mechanical tension and fix it with the sleeve fixing (A) .

Electrical connection from below

Electrical connection from above

A

S

Содержание InLine DCX Next

Страница 1: ...nual Modelnumber DCXNext Electronicallycontrolledinstantaneouswaterheaters 1 Installation instructions user manual 9120 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email ser...

Страница 2: ...2013 814 2013 8 6 Warranty 9 Installation instruction 1 Overview 10 2 Technical specifications 11 3 Dimensions 11 4 Installation 12 Installation site 12 Mounting accessories 12 Installing the wall bra...

Страница 3: ...gs and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immediately...

Страница 4: ...re of 0 2 to 0 4MPa 2 4bar The appli ance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appliance m...

Страница 5: ...n with an external load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions 2 Environment and recycling Operation instruction Note Carefully read...

Страница 6: ...econds to open the info mode After ten seconds all LEDs light up once briefly and then switch off again immediately to confirm that the info mode is active The device status is displayed via the LEDs...

Страница 7: ...m inadvertently running dry Nevertheless the appliance must be vented before using it for the first time Each time the appliance is emptied e g after work on the plumbing system if there is a risk of...

Страница 8: ...r product information listed elsewhere may result in different test conditions The power consumption was determined in compliance with standardized measurement method based on EU guidelines The real e...

Страница 9: ...r the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from n...

Страница 10: ...afety pressure cut out SDB Connecting terminal Frame Cold water connection Fine filter Water splash protection sleeve DCX Next hood Non return valve Flow sensor Thermal sensor Thermal sensor Outlet pi...

Страница 11: ...ype pressure resistant pressureless Heating system Bare wire heating system IES 15 C Required specific water resistance Specific electrical conductivity 1100 cm 90mS m Inlet temperature 30 C Flow rate...

Страница 12: ...ly with water connections left The appliance complies with protection type IP25 and may therefore be installed in protection zone 1 according to VDE 0100 part 701 IEC 60364 7 In order to avoid thermal...

Страница 13: ...according to the template and drill them using a 6mm drill Insert the included dowels 3 To open the appliance pull down the faceplate and unscrew the main hood screw Lift the hood carefully remove the...

Страница 14: ...ht cor rections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to screw on the water connection pipes of the appli ance without applying force 2 Scr...

Страница 15: ...low reducer D into the hot water connection piece The hot water and cold water connectors must then be screwed into the inch union nut of the appliance inlet and outlet pipe together with the inch sea...

Страница 16: ...water heaters IN 82250 can be connected to phase con ductor L2 To avoid possible jitter of the load shedding relay caused by low power consumption low temperature set point and low water flow rate th...

Страница 17: ...nal to the upper foot Affix the connecting terminal again 6 Strip the individual wires of the connecting cable and plug them in the connecting terminals according to the wiring diagram The appliance m...

Страница 18: ...lect the maximum allowable power rating depending on the local situation To do this take the auxiliary tool A from the holder on the electronics cover and turn the switch to the desired value 2 Put th...

Страница 19: ...must not be pinched or squeezed Then switch on the power again e g via activating the fuses Maintenance work must only be conducted by an authorised professional 8 Maintenance work Cleaning and replac...

Страница 20: ...0 34379 v1 20 Okt 2022 ZIP DCX Next Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk www zipwater co uk ZipWaterUK TrafalgarHouse Rash sGreen Dereham Norfolk N...

Отзывы: