ZinCo GmbH
Lise-Meitner-Strasse 2 ∙ 72622 Nürtingen ∙ Germany
Phone +49 7022 6003-0
[email protected] ∙ www.zinco-greenroof.com
Installation Instructions
Fallnet
®
SB 200-Rail
Important:
In general, the material temperature during installation should not be
below +5 °C.
Applying the graphite or copper paste which is included in the delivery
will prevent the stainless steel screws from seizing.
2.4 Application of the required load
Prior to the application of the required load the on-site situation needs to
be documented and photographed if necessary.
The solar bases of Fallnet
®
SB 200-Rail must be evenly filled and
covered with suitable bulk material. In the case of solar installations, this
can be done with ZinCo system soil, Zincolit
®
, gravel with a grain size of
16/32 mm or a comparable bulk material. In the case of railings, the ballast
can also be provided by a slab covering laid in a bed of chippings.
* These minimum values include the dead weight of the superstructures
(e.g. PV modules, collectors, railings, etc.) and apply to the function as
fall protection. If higher superimposed loads have to be applied according
to the static calculation, e.g. to prevent a solar installation from lifting due
to wind suction, these must of course be taken into account!
The values apply for the dry state of the bulk material. The layer thickness of
the bulk material used depends on its bulk density (dry).
To achieve the 120 kg/m², for example, the solar bases must be evenly
filled and covered with at least 85 mm of Zincolit
®
or System Substrate
Sedum Carpet. 40 mm thick concrete slabs laid in a 40 mm thick gravel
bed, including backfilling, result in a superimposed load of approx. 180 kg/m².
For reasons of UV protection, a gravel cover must reach at least 50 mm
above the upper edge of the plastic grid.
Important: Direct contact between the load (bulk material) and the
grid elements is required at all times.
3 Completion
Make sure that all work is done professionally according to the site
planning and the Installation Instructions. Check the identification label at
the point of entry, it must be permanently well recognizable. Only rail
systems marked with a label may be used.
3.1 Installation documentation
The installation documentation allows for providing evidence of a
professional installation to the client. Furthermore it is an indispensable
base for future inspections of the Fallnet
®
SB 200-Rail fixing devices.
A template for the installation documentation is available as a PDF file
from the manufacturer. Document copies must be handed over to the
client after installation and must be kept on the object for future inspections
of the Fallnet
®
SB 200-Rail.
Required information:
- address of property
- installation company
- technician in charge of installation
- Fallnet
®
SB 200-Rail serial number (see runner or label)
- details of superimposed load (type of bulk material, weight,
include delivery note if relevant)
- site planning (please include serial number(s) here too)
The site planning should be affixed to the building where it is clearly
visible, e.g. at the roof access point.
Statement issued by the technician in charge of installation (signature):
- the Fallnet
®
SB 200-Rail Installation Instructions were adhered to
- installation was carried out as planned
- the minimum load requirements have been adhered to
- photo documentation, in particular of details that are no
longer visible after installation.
3.2 Handing over the Fallnet
®
SB 200-Rail documentation to the client/
owner
The delivery scope includes the following documents, which the installer
must hand to the client:
- Installation Instructions and User Instructions
- Installation documentation
- Control card, Fallnet
®
SB 200-Rail
must be maintained and
inspected regularly. Please enter serial numbers (see runner or
label)
- Site planning
3.3 Queries
Should you have any queries, or be unsure about the correct use/
installation of the product or require further detailed information for your
own specific building project, please contact ZinCo GmbH, Hotline
phone +49 7022 6003-0.
Documentation - Corresponding templates can be found under:
https://zinco-greenroof.com/downloads
Required load* for Fallnet
®
SB 200-Rail:
min. 120 kg/m² (roof inclination 0° to 2°)
min. 140 kg/m² (roof inclination > 2° to 5°)