ZIMO MX82D Скачать руководство пользователя страница 5

                                         ACCESSORY DECODER  MX82

 

Page 5                                                       

 

# 553

resp

.:

  

# 41

Address and sub
addresses for
Servo output 
1 and 2

0 - 33
or

100 -
      133

110

This CV determines whether the servos are 
controlled with the same address as in CV
# 513, 521 or the next one higher
(default!!!) and which of the 4 function keys
F0 - F3 are used.

ONES DIGIT values (for Servo 1):
    = 0: F0 (#1 with Zimo cab)
    = 1: F1 (#2 with Zimo cab)
    = 2: F2 (#3 with Zimo cab)
    = 3: F3 (#4 with Zimo cab)

TENS DIGIT values (for Servo 2):
    = 0: F0 (#1 with Zimo cab)
    = 1: F1 .......    continue as above.
HUNDREDS DIGIT values:
   = 0 Address as per CV # 513, 521
   = 1 The servos operate on the next
        higher address, that is: address as
        in CV # 513,521 + 1.

# 554

resp.:
  # 42

Ad dress and sub 
ad dresses for 
Servo out put 
3 und 4

0 - 33

or

100 -
      133

132

Use as CV # 553 above but for 
servo out puts 3 and 4.

ONES DIGIT for servo 3;

TENS DIGIT for servo 4

;

HUN DREDS DIGIT:
   

= 0 Ad dress as per CV # 513, 521

   = 1 The ser vos op er ate on the next
                higher ad dress, that is: ad dress
        as in CV # 513,521 + 1.

# 555

resp.:
  # 43

Motor acceleration

(with pulse width
modulation, only if CV
#515, 516, 517 or  518 > 0)

0 - 255

0

Slow acceleration of motor drive;
time in 1/10 of a second (max. 25 sec) until
the motor connected reaches its full speed
(according to CV #557).

# 556

resp.:
  # 44

Mo tor deceleration

(with pulse width mod u la -
tion, only if CV #515, 516,
517 or  518 > 0)

0 - 255

0

Slow de cel er a tion of mo tor drive;time in
1/10 of a sec ond (max. 25 sec) un til the mo tor
co mes to a com plete stop.

# 557

bzw.:
  # 45

Mo tor speed

(with pulse width mod u la -
tion, only if CV #515, 516,
517 or  518 > 0)

0 - 255

255

Max i mum mo tor speed (af ter ac cel er a tion
phase) by means of pulse width mod u la -
tion.

= 255: high est pos si ble speed.

# 558

bzw.:
  

# 46

Back-EMF

0 - 255

(Ver sion  3

and

above)

0

Se ver ity of mo tor con trol
= 0: no back-EMF

# 561

resp.:
  

# 49

Servo protocol

0

= 0:  Servo pro to col with pos i tive pulses.

= 1:  Servo pro to col with neg a tive pulses.

562

resp.:
  

# 50

Ser vo 1

Left stop

0 - 255

0

De ter mines left stop po si tion.  

# 563

resp.:
  

# 51

Ser vo 1

Right stop

0 - 255

255

De ter mines right stop po si tion.

# 564

resp.:

  

# 52

Ser vo 1

Rotating speed

0 - 255

30

The en tered value rep re sents the time (in 1/10
sec) needed to drive the servo be tween de fined
stops. Max i mum 25 sec. De fault value “30” = 3
sec (plus ac cel er a tion and de cel er a tion times
pro grammed in CV #565).

# 565

resp.:
  

# 53

Ser vo 1

Ac cel er a tion and
deceleration

0 - 255

20

Slow ac cel er a tion and de cel er a tion of servo;
time in 1/10 of a sec. (max. 25 sec), de fault value
“20” = 2 sec.

          # 566 as above,
                    # 567    

for                        

                       

#568

     Servo 2                        

          # 569
          

resp

.:

             # 54
             # 55
             # 56
              # 57

# 570  as above     
# 571  for                     
# 572   

 Ser vo 3

# 573

resp.:
  # 58
  # 59
  # 60
  # 61

     # 574   as above
     # 575   for
     # 576  

 Ser vo 4

     # 577
     resp.:
        # 62
        # 63
        # 64
        # 65

Содержание MX82D

Страница 1: ...tioned in this manual Such missing or incomplete functions can be installed later by updating the software or replacing the EPROM only at the factory Beginning in October 2004 all decoders MX82 with SW version 3 and up can be updated by the end user see page 3 Software updates are available for the end user free of charge except for the purchase of the programming tool Updates and alterations perf...

Страница 2: ...ing with production date September October 2004 Zimo decoders are equipped to handle a software update by the end user That requires a Zimo MXDECUP decoder update module available in November 2004 as well as acomputerwithWindows operatingsystemandInternetconnection fordown loading the new software from Zimo s web site The update module is not tied toaZimosystemandcanthereforebeusedwithother DCC sy...

Страница 3: ...ss but also a sub address 2 sub addresses for the MX82V The address is required for decoder access with a cab and the sub address determines with which function key the turnout will be operated Although the MX82may be installed immediately anaddresshas tobe assignedbefore itiscon nected to the layout wiring Assigning a new address is not possible with several MX82 connected in parallel to the trac...

Страница 4: ... Identifies the decoder as accessory decoder 546 resp 34 Light uptime only when continuous on is selected as in CV 515 516 517or518 0 0 255 10 For prototypical signal operation Time in 1 10 of a second for a total range of 25 seconds until the light bulb reaches its full intensity 547 resp 35 Light updelay only when continuous on is selected as in CV 515 516 517or518 0 0 255 0 For prototypical sig...

Страница 5: ...eed according to CV 557 556 resp 44 Motor deceleration with pulse width modula tion only if CV 515 516 517 or 518 0 0 255 0 Slow deceleration of motor drive time in 1 10ofasecond max 25sec untilthemotor comes to a complete stop 557 bzw 45 Motor speed with pulse width modula tion only if CV 515 516 517 or 518 0 0 255 255 Maximum motor speed after acceleration phase by means of pulse width modula ti...

Страница 6: ...ecoderhas its own CV for power on time e g one uses 515 thenext 516 and so on andthere is no chance that another decoder gets re programmed unintentionally If 2 motorized switch machines are used with an MX82V both applicable po wer onCV s e g 515and516 havetobeset toanappropriatevalue e g 30 In order toutilize the4 sub addresses which are available for each accessoryde coder address several MX82d...

Страница 7: ...usly with solenoid or motorized turnouts or signals or exclusively Attention The 4 servo connections are set to the next higher address by default through the CV settings 553 110 and 554 132 the servos do not oper ate with the accessory address stored in CV 513 and 521 but rather ac cordingto the valuesin CV 513 and 521 1 For example Ifaddress 36 is selected the servos operate at address 37 and Fu...

Страница 8: ...to the single wires MOTORIZED SWITCH MACHINES AND SIGNALS Such units are connected with 2 wires The blue wire is not needed in this application The other wires grey orange are connected with the switch machine The power on time has to be pro grammed with CV 515 516 517 depending on the sub address used EPL SWITCH MACHINES LGB EPL switch machines are electrically identical to the motorized switch m...

Страница 9: ...meets the natural requirements of many such machines For example an old fashioned non electronic model railroadpower packmaybe used But pay attentionthatonlytheDCoutput is suitable Under no circumstances should the AC output be used An ordinarytransformer e g 16 18V output witharectifieraddedcan also be used instead of a model railroad power pack Thepositive wireofthissupply isconnectedtothecommon...

Страница 10: ... Turnouts 1 4 at the LENZ cab MX82 address 1 Sub address 0 3 Turnouts 5 8 at the LENZ cab MX82 address 2 Sub address 0 3 Turnouts 9 12 at the LENZ cab Address 3 DEFAULT Sub address 0 3 and so on If forexample anMX82istobeoperatedwith number10 thevaluefortheaddress in CV 1 must be 3 and the value for the sub address in CV 33 must be 1 If the MX82 servo outputs are used note that these are assigned ...

Отзывы: