9  Transportation/storage/preservation

 

Transport and storage of the product must be done only with the original packaging.

 

If the product has already been installed on the superordinate machine unit, care must be taken during transport to 

ensure that no unexpected movements can occur. 

 

Before commissioning the product and after transport, check all power and communication connections as well as 

all mechanical connections.

 

If the product is stored for an extended period, the following points are to be observed:

 

Keep the storage location as dust-free and dry as possible.

 

Avoid temperature fluctuations/observe and adhere to the temperature range.

 

Avoid wind/drafts/water condensation formation.

 

Cover the product with a weatherproof, tear-resistant foil to prevent dust.

 

Pack the product and do not expose it to direct sunlight during storage.

 

Clean all components. There must be no soiling left on the components.

 

Visually inspect all components.

 

Remove all foreign substances.

 

Properly remove potential corrosion spots.

 

Close electrical connections using suitable covers.

INSTALLATION AND OPERATING INSTRUCTIONS: 

ZR1000-A

DDOC01702 / -

EN / 2022-09-27

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание ZR1000-A Series

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Axis compensation module pneumatic ZR1000 A series DDOC01702 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...y notices 5 3 Proper use 6 4 Personnel qualification 6 5 Product description 6 5 1 Forces and torques 6 5 2 Type plate 6 6 Functional description 7 7 Technical data 7 8 Accessories scope of delivery 7...

Страница 4: ...ding these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Страница 5: ...permission of the manufacturer Use of the product under extreme conditions such as aggressive fluids or abrasive dusts Additional drilled holes or threads Zimmer GmbH shall accept no liability for an...

Страница 6: ...f 8 bar The product is designated for use in closed facilities Direct contact with perishable goods food is not permitted 4 Personnel qualification Installation commissioning and maintenance may only...

Страница 7: ...FORMATION You can find the information in the technical data sheet on our website This data varies within the series depending on the specific design Please contact Zimmer Customer Service if you have...

Страница 8: ...Keep the storage location as dust free and dry as possible Avoid temperature fluctuations observe and adhere to the temperature range Avoid wind drafts water condensation formation Cover the product w...

Страница 9: ...llation may only be carried out by qualified personnel in accordance with these installation and operating instructions Switch off the power supply before any assembly installation or maintenance work...

Страница 10: ...supply NOTICE You can find the information in the technical data sheet on our website Close off unused connections using suitable dummy plugs The authorized connections that are available can be found...

Страница 11: ...nsors The sensor is used for magnetic piston position sensing 7 8 9 Install the sensor holder on the product using the mounting screw 7 Sensor holder 8 Mounting screw 9 Sensor INFORMATION More informa...

Страница 12: ...product is maintenance free as mentioned above perform a regular visual inspection to check for any corrosion damage or contamination Have maintenance work be performed by Zimmer Customer Service whe...

Страница 13: ...he specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents...