INSTALLATION AND OPERATING INSTRUCTIONS:
SB/SBZ series of swivel jaws
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
Phone: +49 7844 9138-0
●
Fax: +49 7844 9138-80
●
www.zimmer-group.de
DDOC00246
enu / 2018-02-21 / b
► The swivel jaws of the SB/SBZ series operate maintenance-free for up to 10 million swiveling cycles.
7. Maintenance
INFORMATION:
The actual service life of the swivel jaws is dependent on many factors:
•Drive with filtered compressed air, dry or lubricated
If operation begins with lubricated air, then the swivel jaws must always be operated
with lubricated air after that
• Operation in one direction, operation with change of direction
• Environmental conditions (humidity, temperature, etc.)
• The performance data for the corresponding use/handling weight
• Shock absorber setting
INFORMATION:
Complete removal of the swivel jaws can only be carried out by Zimmer.
NOTE:
Always ensure that the adjustment screws make contact with the respective limit stop surfaces, so that the shock
absorber does not serve as an end stop.
6.5 End position damping – SBZ series
The following steps should be carried out to adjust the end position damping
7
:
► Loosen the shock absorber locknut
hm
and turn the shock absorber
hn
clockwise until
the drive flange
1
moves
► Unscrew the shock absorber by 3-4 turns counterclockwise (decreases damping)
► Loosely attach the locknut
► Remove persons, all tools and other objects from the swivel range of the swivel jaws
► Connect the swivel jaws to the energy supply and fill them with properly prepared air
► Open the adjustment screws of the flow control valves
ho
by a few turns
► Pressurize the swivel jaws with compressed air on alternating sides and check the settings
► If necessary, make adjustments using the adjustment screws of the flow control valves and
by adjusting the shock absorber
► Clamp the shock absorber locknuts
An ideal setting is reached if a uniform swivel movement and an approach to the limit stops with
exhaust air throttling is guaranteed.
ho hm hn
Interval
Maintenance work
Description
1
monthly
Visual inspection
Check for damage, corrosion, contamination
Strength of all threaded connections, function of all movable elements
Freedom of movement of all hoses and lines
Leaking at the pneumatic connections
Function of the sensors and the electrical connections
2
monthly
Cleaning
Cleanliness of the sensors and contact stability of the connections
Cleanliness of the surfaces and contact elements for the workpiece holder
Apply corrosion protection agent to the housing
Driven with compressed air in accordance with ISO 8573.1 with the following parameters:
-
Solid
content
class
2
-
Moisture
content
class
4
- Oil content: Class 1 (non-lubricated air)
Despite the aforementioned maintenance-free feature, we recommend regularly checking the swivel jaws in accordance with the gen-
eral duty to exercise proper care. For this purpose, we recommend the intervals listed in the table.