INSTALLATION AND OPERATING INSTRUCTIONS:
SB/SBZ series of swivel jaws
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
Phone: +49 7844 9138-0
●
Fax: +49 7844 9138-80
●
www.zimmer-group.de
DDOC00246
enu / 2018-02-21 / b
5.3 Energy supply
Type
Pneumatic connections
SB32-D
4 x M5/2 x M3
-
SB40-B
2 x M5
-
SB54-B
2 x M5
-
SB50-90/-180
6 x M5
-
SB74-90/-180
6 x M5
-
SB100-90/-180
2 x M5
4 x G 1/8"
SB150-90/-180
-
6 x G 1/4"
SB190-90/-180
-
6 x G 1/4"
The existing pneumatic connections are shown as A and B in the dimensional drawings of the product data sheets.
Alternatively, potential connections are shown with A‘ and B‘.
A/A‘:
Swiveling
to
90°
or
180°
B/B‘:
Swiveling
to
0°
*) Example
Drawing SB 100-90
6. Commissioning
6.1 Adjusting the swivel angle – SB series
The swivel angle is preset to 180° at the factory (Image
!
)
The swivel angle can be reduced to 90°by replacing the factory-installed limit stop
3
.
(Image
@
)
The swivel jaw is equipped with external limit stops
5
, which allow the swivel angle to be
adjusted a maximum of +/- 3° per limit stop.
► Depressurize the swivel jaw
► Loosen the locknut at the respective limit stop
► Adjust the adjustment screw at the respective limit stop
It must be ensured that the adjustment screw always makes solid contact with the
respective stop surface
► Tighten the locknut
!
@
3 5