9.5 Installing the power supply
CAUTION:
Malfunction due to improper power supply installation
Installing the power supply correctly ensures that the motor spindle will function properly.
Ö
Always install flexible power supply lines.
NOTICE:
Function of the motor spindle is ensured
The function of the motor spindle is ensured if:
•
The power supply lines have adequate dimensions
•
The power supply lines are used that are as short as possible and shielded throughout their entire length
If the power supply lines do not have adequate dimensions, the motor spindle might have an insufficient supply.
Ö
Fault or damage to the motor spindle
INFORMATION:
The bending radius of the power supply lines must not fall below the minimum value!
Cables that are hanging freely must be affixed!
Ö
Excessive movement stress or crushing must be avoided.
Refer to the technical datasheet for the wiring diagrams, plug coding and fluid connections.
E
XD1
XG3 (optional)
XG2
PE
A
KR
AZ
AZ
F
SPL
A
Release the tool
XD1
Power connection and signal
connection
AZ
Clamp the tool
XG2 Signal connection
SPL Sealing air
XG3
Position sensor and speed sensor
(optional)
KR
Cone cleaning
F/E Zu- und Rückführung Kühlsystem
PE
Schutzleiteranschluss
NOTICE:
Ö