57
Error code
Error
Possible cause
Measure
0x0000
Device is ready for operation.
-
-
0x0001
Motor controller is switched off.
•
Motor controller has not yet
been activated.
•
Motor controller has been
switched off.
•
Motor controller was
switched off for device
protection.
►
Switch on the motor
controller.
0x0100
Actuator power supply is not
present or is too low.
•
Actuator power supply is not
connected
•
Actuator power supply is not
sufficient
•
Cable break
•
STO input circuit is
interrupted.
►
Check the actuator power
supply.
►
Switch on the STO input
circuit.
0x0101
Temperature above maximum
permitted temperature.
• Ambient temperature is too
high.
•
Overload of the products.
►
Provide sufficient ventilation/
cooling/connection.
►
Check that the product
moves freely.
0x0102
Max. permitted temperature
undershot.
• Ambient temperature is too
low.
►
Provide an adequate
operating temperature.
0x0206
Motion task cannot be executed
(CRC error).
•
Internal error
►
Apply the process data via a
handshake.
►
Please contact Zimmer
Customer Service.
0x0300
ControlWord is not plausible.
•
Multiple bits were set in the
ControlWord.
►
In the ControlWord, check
that only one bit is set.
0x0301
Positions are not plausible.
• Transmitted positions are
not plausible.
• Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0302
GripForce is not plausible.
• Transmitted GripForce is not
plausible.
• Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0303
DriveVelocity is not plausible.
• Transmitted DriveVelocity is
not plausible.
• Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0304
PositionTolerance is not
plausible.
• Transmitted PositionTol
-
erance is not plausible.
• Modified process data were
not taken over.
►
Check the transmitted
process data.
►
Apply the process data via a
handshake.
0x0305
Position measuring system not
referenced.
• Position measuring system
is not referenced.
•
A reference run is being
performed.
►
Reference the product.
►
Wait until the reference run
is complete.
14 Error diagnosis