Emergency release of GED6000IL
CAUTION
Risk of injury due to uncontrolled movements
Risk of injury in the event of uncontrolled movement of the product when the power supply is connected.
►
Switch off the power supply to the machine before carrying out any work.
►
Secure the power supply against being switched on unintentionally.
►
Check the machine for any residual energy that may be present.
CAUTION
Risk of injury in case of non-compliance
►
Disconnect the actuator voltage before pressing the emergency release.
The product features an emergency release
that can be mechanically opened with an Allen
key in the event of a power failure.
bq
br
►
Remove the protective cap to reach the
emergency release.
►
Actuate the emergency release with a
corresponding Allen key.
•
Turning counterclockwise opens the
jaws (toward the BasePosition).
►
Make sure that the workpiece is secured
when opening the product.
Design size
Wrench size [mm]
GED6040IL-03-A
2.5
GED6040IL-31-A
2.0
GED6140IL-03-A
3.0
bq
Protective cap
br
Hexagon socket
INFORMATION
►
Carry out another reference run after any emergency release.
►
Please contact Zimmer Customer Service if you have any questions.
13 Gripping force charts
INFORMATION
►
You can find the information in the technical data sheet on our website.
►
Please contact Zimmer Customer Service if you have any questions.
INSTALLATION AND OPERATING INSTRUCTIONS:
GEH6000IL/GED6000IL
DDOC00212 / p