10
6.1 Functional safety
For the overall safety of the function, all three components (stationary part, loose part and storage station) must be taken
into account.
The safety function that ensures secure locking between the stationary and loose part of the product is implemented via
two redundant action channels that consist of a mechanical locking and springs.
Technical supplementary safety measures (sensors) provide a high degree of diagnostic coverage. The product can thus be
classified into control category 3 in accordance with Chapter 6.2.6 of DIN EN ISO 13849-1. According to Figure 5,
Chapter 4.5.4 of the specified standard, the PL d can be achieved with this product.
Fault elimination in accordance with DIN EN ISO 13849-2, Annex A, Table A2 and A3 for the helical compression springs
used can be given.
6.2 Control
INFORMATION
►
You can find the information in the technical data sheet on our website.
►
Please contact Zimmer Customer Service if you have any questions.
6.3 Self-locking mechanism
INFORMATION
The connection of the fixed and loose part takes place via a mechanical self-locking mechanism without an
external power supply. Therefore, in case of a power supply failure (e.g. an emergency stop), the loose part
remains locked in the stationary part.
►
Please contact Zimmer Customer Service if you have any questions.
7 Technical data
INFORMATION
►
You can find the information in the technical data sheet on our website.
This data varies within the series, depending on the specific design.
►
Please contact Zimmer Customer Service if you have any questions.
For the maximum tool weight, refer to the tightening torque/tightening force specified in the technical data, taking into
account the distance to the center of gravity and the mating force of the energy elements.
INSTALLATION AND OPERATING INSTRUCTIONS:
FWR
DDOC01406 / -
EN / 2022-05-10
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com