![Zimmer FWR Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/zimmer/fwr-series/fwr-series_installation-and-operating-instructions-manual_934078012.webp)
12
10 Installation
WARNING
Risk of injury due to uncontrolled movements
Risk of injury in case of unexpected movement of the machine or system into which the product is to be installed.
►
Switch off the energy supply of the machine before any work.
►
Secure the power supply against being switched on unintentionally.
►
Check the machine for any residual energy that may be present.
NOTICE
►
Installation may only be carried out by qualified personnel in accordance with these installation and operating
instructions.
►
Switch off the power supply before any assembly, installation or maintenance work.
►
Install the product on an appropriate mounting surface in accordance with the flatness specifications.
INFORMATION
Requirements for the mounting surface:
• Permissible unevenness: 0.03 mm
Further installation information:
• The mounting screws are not included in the scope of delivery.
• Strength class of the mounting screws is at least 8.8 (DIN EN ISO 4762)
►
Observe the tightening torque of the mounting screws.
►
Verify the permitted load capacity of the required screw connections in accordance with VDI 2230.
INSTALLATION AND OPERATING INSTRUCTIONS:
FWR
DDOC01406 / -
EN / 2022-05-10
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com