background image

Z16FMC Series Motor Control Development Kit

Quick Start Guide

QS007901-1110

Page 15 of 15

DO NOT USE IN LIFE SUPPORT

LIFE SUPPORT POLICY

ZILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPO-
NENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS 
PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF 
ZILOG CORPORATION. 

As used herein

Life support devices or systems are devices which (a) are intended for surgical implant 
into the body, or (b) support or sustain life and whose failure to perform when properly 
used in accordance with instructions for use provided in the labeling can be reasonably 
expected to result in a significant injury to the user. A critical component is any compo-
nent in a life support device or system whose failure to perform can be reasonably 
expected to cause the failure of the life support device or system or to affect its safety or 
effectiveness.

Document Disclaimer

©2010 Zilog, Inc. All rights reserved. Information in this publication concerning the 
devices, applications, or technology described is intended to suggest possible uses and 
may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR PRO-
VIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES, 
OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO DOES NOT 
ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT 
RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECH-
NOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within 
this document has been verified according to the general principles of electrical and 
mechanical engineering.
Z8, ZNEO and Z16FMC are trademarks or registered trademarks of Zilog, Inc. All other 
product or service names are the property of their respective owners. 

Warning:

Содержание Z16FMC Series

Страница 1: ...llowing elements Power supply requirements to power the 3 phase motor supplied with the kit How to run the kit s preloaded sample code in standalone mode How to connect the kit to your development PC...

Страница 2: ...kit and run the sample code in standalone mode Step 1 Connect the 3 Phase Motor to the Board The 24V DC 3 phase motor included with the kit features three spade connectors that plug into spade lugs P...

Страница 3: ...Set Switches For your initial setup set the switches on the board as detailed below Set Direction Switch S2 to the far right position Set Switch S3 to the far right RUN position Set Speed Potentiomet...

Страница 4: ...Z16FMC Series Motor Control Development Kit Quick Start Guide QS007901 1110 Page 4 of 15 Figure 2 Z16FMC Series Development Kit Motor and DBG Connections White wire Green wire Blue wire...

Страница 5: ...equipment AC power cord purchased separately between the AC cord receptacle on the end of the power supply and an electrical outlet Step 4 Connect the 5V DC Universal Power Supply Connect the 5V DC p...

Страница 6: ...bed in this section 1 Stop the preloaded sample code and turn power to the 3 phase motor and MC MDS board off 2 Install the ZDSII ZNEO Series Software 3 Install the USB Smart Cable driver software and...

Страница 7: ...MDS board or application board before connecting a USB Smart Cable to the host PC and development board Windows Vista Observe the following steps to install the opto isolated USB Smart Cable for 32 bi...

Страница 8: ...Windows Logo testing dialog appears select Continue Anyway 3 Select Search for the best driver in these locations and Include this location in search 4 Browse to the following directory and click Next...

Страница 9: ...PC Set the terminal to 57600 8 N 1 1 Ensure that the switches and jumpers on the MC MDS board are set as described in Step 2 Set Switches on page 3 2 Connect and apply power to the development kit as...

Страница 10: ...Program Files ZiLOG ZDSII_ZNEO_ version_number samples Z16FMC Z16FMC_Series 6 Select the Z16FMC_motordemo zdsproj file and click Open The initial ZDSII pro gram screen opens see Figure 4 To view the p...

Страница 11: ...ow to setup the debugger 9 Click OK 10 Click the Rebuild All icon to build the project Wait for the build to complete as indicated by the Build Complete confirmation in the Status window at the bottom...

Страница 12: ...t Kit Quick Start Guide QS007901 1110 Page 12 of 15 Figure 5 Option Bits Warning Dialog Box 12 Click Go to start the program The screen changes as illustrated in Figure 6 on page 12 Figure 6 Zilog Dev...

Страница 13: ...for assistance Verify that you are using ZDSII version 4 12 0 or later Ensure that you are using the unmodified sample project code as described in Execut ing the Sample Code on page 6 Verify that you...

Страница 14: ...the project rebuilds with no errors Verify that the development board is not currently running any code the motor should not be spinning Try reloading the sample project as described in Executing the...

Страница 15: ...perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2010 Zilog Inc All rights reserved Information...

Отзывы: