User
’
s Manual
SP226
11
3.12
Collector emergency cut-off
When the temperature of collector reaches or exceeds 120
℃
, in order to prevent evaporation of heat medium
liquid and protect other components of solar system, solar circulation pump will be stopped compulsively, until
the temperature of collector gets lower.
3.13
Memory function
In case of power failure, solar control system is able to remain the preset parameters unchanged.
3.14
Reset Function
If necessary, all the settings (except time setting) can be reset to the
factory settings.
ì
Press
“
Choose Function
”
button, until
“
”
displays on the
screen.
ì
Press
“
Confirm
”
button, all of parameters will be reset to factory
settings.
3.15
Manual operations
Customers can monitor the flow rate anytime by viewing the signal
“
”
on main operating menu. And when
there are no other operations and it returns to main menu, they can also activate some functions by pressing
different buttons directly.
ì
Press
“
Confirm
”
button to switch on/off solar collector pump
(P1) manually.
ì
Press
“
Cancel
”
button to switch on/off solar circulation pump
(P2) manually.
ì
Press
“ ”
“
”
button repeatedly to check the temperature
values in different part of solar system.