20
Chart 10
display status when perform welding under
Chart 11
Display status after stop
welding under MIG mode
MIG mode
Storage function
Press
mode selection
, can store 3 modes, which are Memory1,Memory2 and Memory3.
4.2.2 Malfunction display
Malfunction display of wire feeder
The panel displays as Chart 12 when the wire feeder is malfunctioning, and the
multifunctional data display
flashes continuously, the machine can not work normally.
Please restart the machine, the panel would display the parameters that were set before
malfunction occurrence.
Malfunction display of over-current
The panel displays as Chart 13 when over-current, and the
multifunctional data display
flashes continuously, the machine can not work normally. Restart the machine, the panel
would display the parameters that were set before malfunction occurrence.