Extra Vegetables Zigen HX-88 driver 

 

Page 4 of 8 

 

We suggest that before you make the serial connection in Composer that you ensure that 
the physical serial cable is connected and the Zigen HX-88 is switched on.  You should 
use the serial cable provided with the HX-88. 
 
If you do this it allows the driver to immediately query the HX-88 for its status and 
provide you with confirmation that the connection is good. 
 
Once you have made the connection the Driver Information box will show the name of 
the switch.  This will be HX-88 as shown unless you have changed the name. 
 

 

 
If the name is shown then you know the driver is successfully communicating with the 
switch.  If it is not you should check both your physical and Composer connections. 
 

Test the Driver 

You can now test the driver.  If you highlight the matrix in System Design and double 
click it the control window will appear. 
 
This will show the current Input to Output 
combinations highlighted in Green.  You 
can now control the matrix from this 
screen.  The green highlight will move to 
the new input-output combination when 
the driver receives confirmation from the 
switch that the switch has been made. 
 
You will also be able to follow the switch 
changes on the front panel of the switch. 
 
Once you are satisfied that all is working 
correctly you can move onto making the 
optional settings on the driver. 

Содержание HX-88

Страница 1: ...tch Serial Driver Contents Introduction 2 Setup and Test the Zigen Unit 2 Test before you install 2 Add the driver to your project 3 Configuring the Driver 3 Make Your Connections 3 Test the Driver 4...

Страница 2: ...nd digital pathway is essential for maintaining the highest possible image quality from all sources The Extra Vegetables driver is available free to Control4 dealers No activation code is required Set...

Страница 3: ...Manufacturer Zigen It will appear as AV Switch as Configuring the Driver The driver now needs to be set up to work with the system Make Your Connections With everything set up you can now make the con...

Страница 4: ...name is shown then you know the driver is successfully communicating with the switch If it is not you should check both your physical and Composer connections Test the Driver You can now test the driv...

Страница 5: ...to see if any such changes occur then you can enable this function The driver will poll the switch every 15 seconds Any changes detected will be reflected in the standard Control4 variables for the s...

Страница 6: ...s are displayed on the Lua tab Show inputs connected This will show which inputs on the switch have something connected to them This requires that the source devices be powered so that they can provid...

Страница 7: ...y for Switch Status in the driver properties or execute a device specific command to update them EDID_x_STATE This will be set either to Fixed or Output 1 depending on the settings on the HX 88 In ord...

Страница 8: ...that defined on the Properties tab There should be no reason to adjust this from 0 in most cases Press the Display Switch Info Action button If nothing is shown on the Lua tab and you are sure all the...

Отзывы: