Variables 

Matrix switches in Control4 have a standard set of VIDEO_OUTPUT_xx_INPUT variables 
which are populated to show which input is connected to which output.  These are 
updated by the driver as Director switches the matrix.  In order for these variables to be 
updated if a change is made directly on the switch or via IR then you must enable Query 
for Switch Status in the driver properties or execute a device specific command to 
update them. 
 
In addition a number of other variables are populated and you can program on the event 
of any of these changing.   
 
INPUT_x_STATE  True if the switch senses an input (source) device is powered and 

connected to the switch.  In order for these variables to update you 
must either enable Query for Connection Status in the driver 
properties or execute a device specific command to update them. 

 
OUTPUT_x_STATE True if the switch senses an output (sink) device is powered and 

connected to the switch.  In order for these variables to update you 
must either enable Query for Switch Status in the driver properties or 
execute a device specific command to update them. 

 
EDID_x_STATE 

This will be set either to ‘Fixed’ or ‘Output 1’ depending on the 
settings on the HX-88.  In order for these to update you must either 
enable Query for Connection Status in the driver properties or execute 
a device specific command to update them. 

 

Actions 

The driver supports the standard Connect and Disconnect commands for each output.  In 
addition the following Device Specific Commands are also provided. 
 
Set EDID 

This allows you to set the EDID for an input either to the Fixed 
standard EDID or to copy it from Output 1 

 
Get Input/Output Status  This command interrogates the switch to find the current input 

to output settings.  This information is then used to update 
Control4.  This is useful to ensure that Control4 is periodically 
aware of any manual switches that have been made on the 
unit. 

 
Get connection status 

This command interrogates the switch to see which Inputs and 
Outputs are connected and powered.  It updates the driver 
variables associated with this feature. 

 
Get EDID status 

This command interrogates the switch to report the EDID 
setting on each of the inputs.  It then updates the driver 
variables associated with this feature. 

 

Содержание HX-88

Страница 1: ...tch Serial Driver Contents Introduction 2 Setup and Test the Zigen Unit 2 Test before you install 2 Add the driver to your project 3 Configuring the Driver 3 Make Your Connections 3 Test the Driver 4...

Страница 2: ...nd digital pathway is essential for maintaining the highest possible image quality from all sources The Extra Vegetables driver is available free to Control4 dealers No activation code is required Set...

Страница 3: ...Manufacturer Zigen It will appear as AV Switch as Configuring the Driver The driver now needs to be set up to work with the system Make Your Connections With everything set up you can now make the con...

Страница 4: ...name is shown then you know the driver is successfully communicating with the switch If it is not you should check both your physical and Composer connections Test the Driver You can now test the driv...

Страница 5: ...to see if any such changes occur then you can enable this function The driver will poll the switch every 15 seconds Any changes detected will be reflected in the standard Control4 variables for the s...

Страница 6: ...s are displayed on the Lua tab Show inputs connected This will show which inputs on the switch have something connected to them This requires that the source devices be powered so that they can provid...

Страница 7: ...y for Switch Status in the driver properties or execute a device specific command to update them EDID_x_STATE This will be set either to Fixed or Output 1 depending on the settings on the HX 88 In ord...

Страница 8: ...that defined on the Properties tab There should be no reason to adjust this from 0 in most cases Press the Display Switch Info Action button If nothing is shown on the Lua tab and you are sure all the...

Отзывы: