background image

STW12V  

12470-0710-00

  

Page

 

3 / 8 

www.ziehl.de 

  

 
 

1  General Notes 

 
Compliance with the following instructions is mandatory to ensure the functionality and safety of the 
product.  If  the  following  instructions  given  especially  but  not  limited  for  general  safety,  transport, 
storage, mounting, operating conditions, commissioning and disposal / recycling are not observed, 
the product may not operate safely and may cause a hazard to the life and limb of users and third 
parties.  
Deviations  from  the  following  requirements  may  therefore  lead  both  to  the  loss  of  the  statutory 
material defect liability rights and to the liability of the buyer for the product that has become unsafe 
due to the deviation from the specifications. 

 

2  Application and brief description 

ZIEHL current relays in the OR circuit are particularly suitable for applications where dusts, fumes, vapours or 
gases are generated at various electrical consumers, which must be removed by a central extraction system. 
An integrated shutdown delay controls the operation of the extraction system after working hours. 
Automatic actuation with 12 inputs with adjustable response threshold. 
Current is detected using current transducers type STWA1(H), current sensors S1 (also DC) or potential free 
contacts. 
If current is detected on at least one input, the current sensor turns on or a contact closes, the built-in relay 
turns on. If the current is turned off in all monitored circuits or if it falls below the set response threshold (for 
detection with STWA1(H)), the output relay disconnects with the set delay. 
An adjustable response threshold allows the user to allow smaller currents without triggering switching 
operations. For example, the device can be turned on to make adjustments in an electronic circuit (small 
current through a current transducer). However, the extraction will not start until the main motor is turned on 
(high current). 
The adjustable shutdown delay makes it easy to set the delay time value. 

 

3  Functional overview 

  monitoring up to 12 current circuits in an OR circuit

  inputs for current transducer STWA1(H), current sensor S1 and potential free contacts

  switching point adjustable 0.5 - 5 A (only for connection to the converter)

  adjustable switch-off delay 1 - 60 s

  plug-in connection terminals

  low-voltage AC/DC adapter 24-240 V

  distributor housing

Display and controls

 

 

1) 

Response threshold adjustment 
knob for transmitter connection 
with integrated yellow LED: 

  LED is on 

  relay on

  LED flashes 

  relay on

  delay time active

  LED is off 

 

relay off

2) 

Delay time adjustment knob 

 

Содержание STW12V

Страница 1: ...sducers Grid and Plant Protection Operating Manual STW12V updated 2022 09 21 Um For more information and help about this product please scan the QR Code or choose the following link STW12V Operating manual Quick guide Datasheet Connection diagram CAD Data Firmwareupdates FAQ Videos about installation and settings Certificates STW12V 12470 0710 00 Page 1 8 www ziehl de Current Relay 12 inputs in OR...

Страница 2: ...ew 3 4 Display and controls 3 5 Connection diagram 4 6 Important notes 5 7 Assembly 5 8 Detailed description 5 8 1 Connection of current transducer STWA1 H 5 8 2 Current sensor or contact connection only 6 8 3 Mixed operation Transducers sensors and contacts can also operate in mixed mode 6 9 Technical data 6 10 Type V4 8 11 Disposal 8 ...

Страница 3: ...rent transducers type STWA1 H current sensors S1 also DC or potential free contacts If current is detected on at least one input the current sensor turns on or a contact closes the built in relay turns on If the current is turned off in all monitored circuits or if it falls below the set response threshold for detection with STWA1 H the output relay disconnects with the set delay An adjustable res...

Страница 4: ...STW12V 12470 0710 00 Page 4 8 www ziehl de 5 Connection diagram Note When using STWA1H current transducers instead of STWA1 ensure correct wiring of the connections o STWA1H 1 12 o STWA1H ...

Страница 5: ...f a current greater than the set value I flows through at least one of up to 12 monitored wires the relay activates yellow LED is on If the value falls approx 0 3 A below the inrush current yellow LED flashes the relay switches off again after the delay time set with the t adjustment knob has elapsed yellow LED goes out Failure free and safe operation of the equipment requires that it is properly ...

Страница 6: ...urrent I does not work Tipps Response threshold is too high current flow in the wire is too low wires pass through the current transducer STWA1 H several times Response threshold is too low base load current must be extinguished connect a resistor 0 25 W 200 V before the corresponding input of STW to the current transducer STWA1 H 750 Ω resistor increase by a factor 2 330 Ω resistor increase by a ...

Страница 7: ...on and icing Measuring inputs max 30 V max 3mA Connection current transducer STWA1 or STWA1H current sensor S1 see Us from STW12V potential free contacts total connection of the listed sensors Switching point limit value Limit value I current adjustable via STWA1 AC 0 5 5 A Tolerance 20 Current sensor S1 or not adjustable contact not adjustable Switch off delay adjustable 1 60 s Reception delay ap...

Страница 8: ...t panel 6 Position downward 7 Snap on wall mount with screws Screw hole Ø 4 2 mm for fixing to the wall with screws Ø 4 2 mm 11 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions ZIEHL is registered with the EAR Foundation under WEEE no DE 49 698 543 70 Option 5 7 6 58 48 16 5 4 1 2 3 61 8 45 3 90 116 98 ...

Отзывы: